Parameter Viewer

Document ID ca-bc-psghwmf-2020-06-22 Title Plans and Specifications Guidance for Hazardous Waste Management Facilities URL unknown Jurisdiction /ca/bc Subdomain(s) Wastewater, Stormwater, Industrial water Language en Status completed Analyzed at 2026-03-15 10:17:06.913225+00:00 Relevance Technical guidance for designing and siting hazardous waste facilities.

Q Qualitative Requirements (48)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativereportingrecommendedGuidance and Template Utilizationother, wastewaterApplicants should develop documents for submission to the ministry using this guidance and template, and following site-specific application instructions provided during the structured application process.high
#Q002reportingreportingrecommendedTemplate Modificationother, wastewaterWithin the template, text in green italics is for your information only and should be removed prior to submission.high
#Q003reportingreportingguidanceSubmission Language Clarityother, wastewaterThe ministry expects submissions to be written in a manner that allows them to be implemented with certainty and consistency. Avoid the use of language that is ambiguous, vague or qualitative such as: appropriate, reasonable, general, suitable, and regularly.high
#Q004reportingreportingguidanceSpecific Methods and Frequenciesother, wastewaterProvide clarity by stating what will be done and include a specific frequency and method where relevant.high
#Q005administrativereportingguidanceQualified Professional Preparationother, wastewaterQualified professionals are expected to prepare certain sections of the plans and specifications, as indicated below.high
#Q006reportingreportingmandatoryIntroduction Contentother, wastewaterBriefly summarize the nature of the facility. Indicate whether hazardous waste storage, treatment, recycling and/or disposal take place and list the primary waste types the facility manages. State the purposes of the document using the template text provided or similar language.high
#Q007reportingreportingmandatoryLocation and Surroundings Explanationsother, wastewaterWithin this section explain the following: - Surrounding land uses - Nature of the neighboring properties - The topography of the site and/or drainage features - Distance to the nearest downgradient waterbody - Description of underlying aquifer - Description of any sensitive receptors within 500 m of the property, including their distances and direction, including but not limited to: - o Waterbodies - o Drinking water sources (groundwater wells or surface water sources) - o Parks or protected areas - o Daycares - o Schools - o Hospitals - o Other care facilitieshigh
#Q008reportingreportingmandatorySite Location Map Requirementsother, wastewaterThe information described in this section should also be illustrated on a site location map included within the plans and specifications. The site location map must include a scale and a north arrow.high
#Q009reportingreportingmandatoryMap Legibilityother, wastewaterEnsure the map is legible in electronic and hardcopy formats.high
#Q010reportingreportingmandatorySiting Standards Statementother, wastewaterProvide a statement explaining how the location of the facility adheres to each of the siting standards required by section 3 of the HWR.high
#Q011reportingreportingmandatorySiting Standards Supporting Documentationother, wastewaterInclude detailed descriptions, drawings, and any other required supporting documentation in Appendix A to clearly illustrate how the facility complies with the HWR section 3 siting standards.high
#Q012reportingreportingmandatoryAdditional Siting Standards Verificationother, wastewaterIf applicable, this section must describe and provide justification on how the facility meets these additional siting requirements.If applicable to mobile facilities, secure landfills, waste piles, surface impoundments, land treatment facilities, or disposal in secure buildings.high
#Q013reportingreportingmandatorySite Plan Provisionother, wastewaterProvide a site plan for the facility. The site plan shows existing and planned works and key features of the property. ... Ensure the site plan is legible electronically and when printed.high
#Q014reportingreportingrecommendedSite Plan Inclusionsother, wastewaterThe site plan should include: - North arrow and scale - Property boundaries, fences and buildings - Works listed in section 3.1 - Stormwater management features (diversion, collection and treatment works and discharge location) - Topographic features such as slopes or low-lying areas - Any fuel or hazardous product storage facilities - Location of spill response equipment - Locations of fire hydrants and fire extinguishershigh
#Q015reportingreportingmandatoryWorks Descriptionother, wastewaterProvide a detailed description of the works at the facility, include works that will be used for hazardous waste storage, treatment, recycling, and/or disposal and those works related to the management of stormwater effluent and emissions (air contaminants) that are produced incidental to facility operations.high
#Q016reportingreportingmandatoryWorks Location Identificationother, wastewaterThe location of these works must be identified in an attached site plan as described above.high
#Q017reportingreportingrecommendedFacility Specific Works Drawingsother, wastewaterAny works that are designed specifically for the facility, and/or that have manufacturers specifications should have drawings and/or specifications included in Appendix B.high
#Q018reportingreportingmandatoryWaste Names Consistencyother, wastewaterEnsure all waste names used in this section match those provided in Table 1 of the facility's operational plan.high
#Q019reportingreportingmandatoryHazardous Waste Storage Works Detailsother, wastewaterList all equipment used for hazardous waste storage, this may include tanks, drums, bins, totes, sludge pits (structures to contain a waste pile), etc. State the maximum storage capacity for containers greater than 1,000 L and indicate the construction material (e.g. steel, polyethylene, concrete etc.). For barrels, drums, totes, or similar individual storage containers less than 1,000 L each indicate the total capacity for all containers stored in one area (e.g., within a warehouse you may have capacity for 20,000 L, stored in 205 L drums).high
#Q020reportingreportingmandatoryTreatment, Recycling, and Disposal Equipmentother, wastewaterList the equipment used to treat, recycle, or dispose of the hazardous waste. Include a description of the process (e.g. filter crushing, filtration, sterilization, incineration, etc.).high
#Q021reportingreportingguidanceTreatment Sequence Work Detailsother, wastewaterFor treatment processes, each piece of equipment in the treatment sequence is expected to be included in the list of works.Applicable for treatment processeshigh
#Q022reportingreportingmandatoryStormwater Management Equipment Listother, wastewaterList the equipment and works that are used to manage stormwater effluent and emissions at the facility.high
#Q023reportingreportingmandatoryStormwater Management DetailswastewaterIn this section: - Indicate if the facility is entirely paved and/or which portions of the facility are gravel, etc. - Describe the stormwater diversion measures designed to keep stormwater away from hazardous waste management areas. - Describe stormwater collection and treatment within areas where precipitation has the potential to be in contact with contaminants, waste containers, etc. - Describe the routing of stormwater off the property including how and where it is discharged from the property, the nature of the local storm drain (ditch, pipe, combined with sanitary, etc.) and the name and location of the waterbody where stormwater enters the receiving the environment.high
#Q024reportingreportingmandatoryStormwater Features PlottingwastewaterShow the facility stormwater design features including but not limited to those listed above on the site plan or other figure. Reference the figure(s) in this section.high
#Q025reportingreportingmandatoryUnpaved Facility InfiltrationwastewaterIf the facility is not paved, describe the infiltration properties of the facility substrate, the groundwater flow direction and location of the receiving water body.If the facility is not pavedhigh
#Q026reportingreportingmandatoryStormwater Non-Infiltration RationalewastewaterIf stormwater is not expected to infiltrate into groundwater, provide rationale and indicate where it is expected to enter the environment.If stormwater is not expected to infiltrate into groundwaterhigh
#Q027administrativereportingguidanceProfessional Engineer Certificationother, wastewaterIt is expected that a qualified professional (typically a professional engineer) will confirm the facility is designed to meet the requirements of the HWR and will sign and seal design specifications.high
#Q028reportingreportingmandatoryHWR Section Referencingother, wastewaterReference each section of the HWR that relates to facility design and describe in detail how the facility will meet each requirement.high
#Q029reportingreportingrecommendedDesign Requirements Summary Formatother, wastewaterThis section should summarize facility design information in an itemized format and reference design specifications and/or other supporting documentation in appendices.high
#Q030administrativereportingguidanceCertification Signaturesother, wastewaterAll authors of the plans and specifications are expected to sign the document.high
#Q031reportingreportingmandatoryFigures Placementother, wastewaterPlace the location map, site plan, and any other relevant figures directly following the text.high
#Q032reportingreportingmandatoryAppendix A Siting Supporting Documentsother, wastewaterProvide an appendix (Appendix A) with supporting documents that demonstrate how the facility meets the HWR siting standards.high
#Q033reportingreportingmandatoryAppendix Maps Legibilityother, wastewaterEnsure all maps are legible electronically and when printed.high
#Q034reportingreportingmandatoryFigure Siting Annotationsother, wastewaterAnnotate figures to show the facility location in relation to siting features.high
#Q035reportingreportingrecommendedSupporting Documents Organizationother, wastewaterPlease ensure that supporting documents are organized in a manner that facilitates efficient retrieval (e.g. logically sequenced, well labelled, linked to document navigation functions).high
#Q036reportingreportingmandatoryAppendix B Design Specificationsother, wastewaterInclude design and/or manufacturer specifications for relevant components of the facility in this appendix. For example, for pollution control equipment, hazardous waste treatment equipment, containment design, leak detection systems, etc.high
#Q037reportingreportingmandatoryFacility Address Civic Address Provisionother, wastewaterP.O. Box numbers are not acceptable for the facility address. If the facility does not have a civic address, provide alternative location information (latitude and longitude), and driving directions to the facility.high
#Q038reportingreportingmandatoryMaterial Changes Notificationother, wastewaterReminder: Section 43(2)(4) of the HWR requires that the ministry be notified of any material changes to the information provided at the time of application, within 30 days of the date of the change.high
#Q039administrativereportingmandatoryApproval for Plan Changesother, wastewaterAlso, any changes to the content of the plan requires prior written approval of the director.high
#Q040administrativereportingmandatoryAmendment Application Submissionother, wastewaterIn order to provide notification of changes to this registration, or to propose changes to the plans and specifications plan, an amendment application form is required to be submitted to the ministry.high
#Q041reportingreportingrecommendedSubmission Page Numbersother, wastewaterPlease include page numbers in your submissionhigh
#Q042reportingreportingmandatorySummary of Activitiesother, wastewaterInclude a brief summary of activities carried out (or proposed) at the hazardous waste management facility.high
#Q043reportingreportingmandatoryTemplate Works Descriptionother, wastewaterInclude plain language description of the works listed above and reference associated specifications provided in an appendix. Use subheadings to describe different types of works if warranted.high
#Q044reportingreportingmandatoryTemplate HWR Design Headingsother, wastewaterDescribe the facility design under headings corresponding to relevant sections of the HWR. Reference design specifications or other supporting documentation in appendices.high
#Q045administrativereportingguidanceTemplate Modification RationaleotherTemplate text can be modified if equivalent information is included with adequate rationale.Modification of ministry template texthigh
#Q046administrativeunknownguidanceProfessional Accountability Policy ReferralotherFor the definition of a qualified professional and information on the ministry's professional reliance model, please refer to the ministry's Professional Accountability Policy website.high
#Q047administrativeoperationalguidanceFacility Design Certification (Professional Engineer)otherInformation related to facility design is expected to be certified by a professional engineer.high
#Q048reportingreportingmandatoryHWR Part 4 Additional Design HeadingsotherInclude headings for additional design requirements under HWR Part 4 where they apply.Where additional design requirements under Part 4 apply (e.g., PCB storage, incinerators, secure landfills)high

P Quantitative Requirements (7)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001unknownreportingrecommendedDistance to sensitive receptorsotherrequirement<= 500 mDescription of any sensitive receptors within 500 m of the property, including their distances and directionhigh
#P002operationalreportingmandatoryMaximum storage capacity reporting thresholdotherrequirement> 1000 LState the maximum storage capacity for containers greater than 1,000 LApplicable to individual containershigh
#P003operationalreportingmandatoryTotal storage capacity reporting thresholdotherrequirement< 1000 LFor barrels, drums, totes, or similar individual storage containers less than 1,000 L each indicate the total capacity for all containers stored in one areaApplicable to multiple smaller individual containershigh
#P004designunknownmandatoryDistance to Holocene faultotherrequirement100 metersThe facility is [not] located within a 200-year floodplain, within 100 meters of a Holocene fault...Facility siting standard requirementhigh
#P005designunknownmandatoryDistance to land subject to slope failureotherrequirement100 metersThe facility is [not] located... within 100 meters of land subject to slope failureFacility siting standard requirementhigh
#P006designunknownmandatoryFloodplain return periodotherrequirement200 yearThe facility is [not] located within a 200- year floodplainSiting standard compliance in section 3 of the HWRhigh
#P007unknownreportingmandatoryNotification period for material changesotherrequirement30 daysSection 43(2)(4) of the HWR requires that the ministry be notified of any material changes... within 30 days of the date of the changeApplicable to facility contact information, addresses, and plan content changeshigh

D Definitions (9)

Req ID Category Name Context Confidence
#D001ministryMinistry of Environment and Climate Change Strategyhigh
#D002HWRHazardous Waste Regulationhigh
#D003ENVMinistry of Environment and Climate Change Strategyhigh
#D004the ActEnvironmental Management Acthigh
#D005EMAEnvironmental Management Acthigh
#D006emissionsassumed to be equivalent to air contaminants, as defined in EMAhigh
#D007sludge pitsstructures to contain a waste pilehigh
#D008the facilityhazardous waste management facility located at [street address of facility]high
#D009effluentdefined in the Environmental Management Act (EMA)high