| #P001 | operational | reporting | guideline | Toluene | drinking water | unknown | 0.005 mg/L | practical quantitation levels (PQLs) for toluene, ethylbenzene and total xylenes are set individually at 0.005 mg/L | U.S. EPA practical quantitation level | high |
| #P002 | operational | reporting | guideline | Ethylbenzene | drinking water | unknown | 0.005 mg/L | practical quantitation levels (PQLs) for toluene, ethylbenzene and total xylenes are set individually at 0.005 mg/L | U.S. EPA practical quantitation level | high |
| #P003 | operational | reporting | guideline | total xylenes | drinking water | unknown | 0.005 mg/L | practical quantitation levels (PQLs) for toluene, ethylbenzene and total xylenes are set individually at 0.005 mg/L | U.S. EPA practical quantitation level | high |
| #P004 | operational | reporting | guideline | Toluene | drinking water | unknown | 0.024 µg/L | Method 524.3 version 1.0 reported a detection limit of 0.024 µg/L | Method 524.3 version 1.0 | high |
| #P005 | operational | reporting | guideline | Toluene | drinking water | unknown | 0.188 µg/L | The minimum quantitation levels... are 0.188 µg/L and 0.092 µg/L for methods SM 6200B and SM 6200C | Method SM 6200B | high |
| #P006 | operational | reporting | guideline | Ethylbenzene | drinking water | unknown | 0.01 µg/L | Method 524.3 version 1.0 has a detection limit of 0.01 µg/L | Method 524.3 version 1.0 | high |
| #P007 | operational | reporting | guideline | o-Xylene | drinking water | unknown | 0.02 µg/L | Method 502.2 revision 2.1 has an MDL of 0.02 µg/L for o-xylene. | Method 502.2 revision 2.1 | high |
| #P008 | operational | reporting | guideline | Toluene (Method 502.2) | drinking water | requirement | 0.01-0.02 µg/L | Method 502.2 revision 2.1 has an MDL in the range of 0.01–0.02 µg/L, depending on the GC column used. | Method 502.2 revision 2.1 | high |
| #P009 | operational | reporting | guideline | Toluene (Method 524.2) | drinking water | requirement | 0.08-0.11 µg/L | Method 524.2 revision 4.1 has an MDL in the range of 0.08–0.11 µg/L, depending on the GC column and GC/MS interface used. | Method 524.2 revision 4.1 | high |
| #P010 | operational | reporting | guideline | Toluene (Method SM 6200B) | drinking water | requirement | 0.047 µg/L | Method SM 6200B has an MDL of 0.047 µg/L | Method SM 6200B | high |
| #P011 | operational | reporting | guideline | Toluene (Method SM 6200C) | drinking water | requirement | 0.023 µg/L | method SM 6200C has an MDL of 0.023 µg/L. | Method SM 6200C | high |
| #P012 | operational | reporting | guideline | Toluene (Method SM 6200C Min Quant) | drinking water | requirement | 0.092 µg/L | The minimum quantitation levels... are 0.188 µg/L and 0.092 µg/L for methods SM 6200B and SM 6200C, respectively | Method SM 6200C | high |
| #P013 | operational | reporting | guideline | Ethylbenzene (Method 502.2) | drinking water | requirement | 0.01-0.04 µg/L | Method 502.2 revision 2.1 has an MDL in the range of 0.01–0.04 µg/L | Method 502.2 revision 2.1 | high |
| #P014 | operational | reporting | guideline | Ethylbenzene (Method 524.2) | drinking water | requirement | 0.03-0.06 µg/L | method 524.2 revision 4.1 allows MDL values in the range of 0.03–0.06 µg/L | Method 524.2 revision 4.1 | high |
| #P015 | operational | reporting | guideline | Ethylbenzene (Method SM 6200B MDL) | drinking water | requirement | 0.032 µg/L | Method SM 6200B has an MDL of 0.032 µg/L | Method SM 6200B | high |
| #P016 | operational | reporting | guideline | Ethylbenzene (Method SM 6200B Min Quant) | drinking water | requirement | 0.128 µg/L | The minimum quantitation levels... are 0.128 µg/L and 0.112 µg/L for methods SM 6200B and SM 6200C, respectively | Method SM 6200B | high |
| #P017 | operational | reporting | guideline | Ethylbenzene (Method SM 6200C MDL) | drinking water | requirement | 0.028 µg/L | method SM 6200C has an MDL of 0.028 µg/L. | Method SM 6200C | high |
| #P018 | operational | reporting | guideline | Ethylbenzene (Method SM 6200C Min Quant) | drinking water | requirement | 0.112 µg/L | The minimum quantitation levels... are 0.128 µg/L and 0.112 µg/L for methods SM 6200B and SM 6200C, respectively | Method SM 6200C | high |
| #P019 | operational | reporting | guideline | m- and p-xylene (Method 502.2) | drinking water | requirement | 0.01-0.02 µg/L | The MDLs for both m - and p -xylene will be either 0.01 or 0.02 µg/L, depending on the GC column used for this method | Method 502.2 revision 2.1 | high |
| #P020 | operational | reporting | guideline | o-xylene (Method 524.2) | drinking water | requirement | 0.06-0.11 µg/L | method 524.2 revision 4.1 allows MDL values in the range of 0.06–0.11 µg/L for o -xylene | Method 524.2 revision 4.1 | high |
| #P021 | operational | reporting | guideline | m-xylene (Method 524.2) | drinking water | requirement | 0.03-0.05 µg/L | method 524.2 revision 4.1 allows MDL values in the range of... 0.03–0.05 µg/L for m -xylene | Method 524.2 revision 4.1 | high |
| #P022 | operational | reporting | guideline | p-xylene (Method 524.2) | drinking water | requirement | 0.06-0.13 µg/L | method 524.2 revision 4.1 allows MDL values in the range of... 0.06–0.13 µg/L for p -xylene | Method 524.2 revision 4.1 | high |
| #P023 | operational | reporting | guideline | o-xylene (Method 524.3) | drinking water | requirement | 0.01 µg/L | Method 524.3 version 1.0 reports... a detection limit of 0.01 µg/L [for o-xylene] | Method 524.3 version 1.0 | high |
| #P024 | operational | reporting | guideline | m/p-isomeric pair (Method 524.3) | drinking water | requirement | 0.02 µg/L | The method defines m -xylene and p -xylene as an isomeric pair, with a detection limit of 0.02 µg/L | Method 524.3 version 1.0 | high |
| #P025 | operational | reporting | guideline | o-xylene (Method SM 6200B MDL) | drinking water | requirement | 0.038 µg/L | Method SM 6200B... has an MDL of 0.038 µg/L [for o-xylene]. | Method SM 6200B | high |
| #P026 | operational | reporting | guideline | m/p-isomeric pair (Method SM 6200B MDL) | drinking water | requirement | 0.038 µg/L | The other two isomers have been defined as an isomeric pair, and the method reported an MDL of 0.038 µg/L. | Method SM 6200B | high |
| #P027 | operational | reporting | guideline | Total Xylenes (Method SM 6200B Min Quant) | drinking water | requirement | 0.152 µg/L | The minimum quantitation level for method SM 6200B is 0.152 µg/L. | Method SM 6200B | high |
| #P028 | operational | reporting | guideline | o-xylene (Method SM 6200C MDL) | drinking water | requirement | 0.024 µg/L | Method SM 6200C has an MDL of 0.024 µg/L for o -xylene | Method SM 6200C | high |
| #P029 | operational | reporting | guideline | m/p-isomeric pair (Method SM 6200C MDL) | drinking water | requirement | 0.021 µg/L | Method SM 6200C has an MDL of... 0.021 µg/L for the m/p -isomeric pair. | Method SM 6200C | high |
| #P030 | operational | reporting | guideline | o-xylene (Method SM 6200C Min Quant) | drinking water | requirement | 0.096 µg/L | Method SM 6200C has minimum quantitation levels of 0.096 µg/L for o -xylene | Method SM 6200C | high |
| #P031 | operational | reporting | guideline | m/p-isomeric pair (Method SM 6200C Min Quant) | drinking water | requirement | 0.084 µg/L | Method SM 6200C has minimum quantitation levels of... 0.084 µg/L for the m/p -isomeric pair | Method SM 6200C | high |