| #Q001 | monitoring | operational | recommended | Use EDTA for Ca2+ and Mn2+ interferences | drinking water | Ca2+, Mn2+ / use EDTA | When using Colorimetry U.S. EPA 350.1 for ammonia-nitrogen determination and Ca2+ or Mn2+ interferences are present. | high |
| #Q002 | monitoring | operational | recommended | Filter sample for elevated turbidity and colour | drinking water | Elevated turbidity and colour / filter sample | When using Colorimetry U.S. EPA 350.1 and elevated turbidity and colour are present. | high |
| #Q003 | monitoring | operational | recommended | Complex with citrate for high Ca2+ and Mn2+ | drinking water | High Ca2+, Mn2+ / complex with citrate | When using Colorimetry U.S. EPA 350.1 and high Ca2+ or Mn2+ interferences are present. | high |
| #Q004 | monitoring | operational | recommended | Distil or filter water for turbidity | drinking water | Turbidity / distil or filter water | When using Colorimetry U.S. EPA 350.1 and turbidity is present. | high |
| #Q005 | monitoring | operational | recommended | Filter sample for high turbidity or colour | drinking water | High turbidity or colour / filter sample | When using Colorimetry SM 4500-NH3 G (automated phenate method) and high turbidity or colour are present. | high |
| #Q006 | monitoring | operational | recommended | Add EDTA and sodium tartrate for high Ca2+ and Mn2+ | drinking water | High Ca2+, Mn2+ / add EDTA and sodium tartrate | When using Colorimetry SM 4500-NH3 G (automated phenate method) and high Ca2+ or Mn2+ interferences are present. | high |
| #Q007 | monitoring | operational | guidance | Avoid high variability in sample pH | drinking water | Avoid high variability in pH of samples: intensity of colour measured is pH dependent | When conducting ammonia-nitrogen determination using Colorimetry SM 4500-NH3 G (automated phenate method). | high |
| #Q008 | monitoring | operational | recommended | Filter sample for large and fibrous particles | drinking water | Large and fibrous particles / filter sample | When using Colorimetry SM 4500-NH3 H (automated flow injection) and large or fibrous particles are present. | high |
| #Q009 | monitoring | operational | recommended | Distil water for aromatics and amines | drinking water | Aromatics, amines / distil water | When using Colorimetry U.S. EPA 350.2 (nesslerization) and aromatics or amines are present. | high |
| #Q010 | monitoring | operational | recommended | Boil off volatile alkaline compounds at low pH | drinking water | Volatile alkaline compounds / boil off at low pH | When using Colorimetry U.S. EPA 350.2 (nesslerization) and volatile alkaline compounds are present. | high |
| #Q011 | monitoring | operational | recommended | Use dechlorinating agent for Residual Cl2 | drinking water | Residual Cl2 / use dechlorinating agent | When residual Cl2 is present. Applies to: Colorimetry U.S. EPA 350.1, Colorimetry U.S. EPA 350.2 (nesslerization), Titrimetry U.S. EPA 350.2, and Titrimetry SM 4500-NH3 C. | high |
| #Q012 | monitoring | operational | mandatory | Sample distillation requirement for Titrimetry | drinking water | Sample distillation is required | When conducting ammonia-nitrogen determination using Titrimetry methods. | high |
| #Q013 | prohibition | operational | mandatory | Prohibition of HgCl2 sample preservation | drinking water | Elevated concentration of dissolved ions, Hg / do not preserve sample with HgCl2 | When using Potentiometry ammonia ion-selective electrode methods and an elevated concentration of dissolved ions or Hg is present. | high |
| #Q014 | monitoring | operational | guidance | Use distillation to remove interferences for flow injection analysis | drinking water | Some interferences may be removed by distillation | When using SM 4500-NH3 H (automated flow injection) and interferences are present. | high |