Parameter Viewer

Document ID ca-qc-ar-2025-01-28 Title Arsenic URL unknown Jurisdiction /ca/qc Subdomain(s) Drinking water Language en Status completed Analyzed at 2026-04-01 02:27:58.736520+00:00 Relevance Defines the regulatory limit for arsenic in drinking water in Quebec.

Q Qualitative Requirements (8)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001operationalhealthrecommendedALARA principle for arsenicdrinking waterConsidering that arsenic can have serious effects on health, its concentration in drinking water should always be as low as possible.high
#Q002monitoringhealthrecommendedArsenic well water testing frequencydrinking waterYour water should be tested for arsenic at least once during the period of usage of the well, ideally in the spring or fall.Applies to usage of a well.high
#Q003corrective_actionhealthrecommendedAlternative water source usagedrinking waterIf the concentration of arsenic in your well exceeds 0.010 mg/L, use another source, or bottled water, to: Drink, Prepare beverages, Prepare feeding bottles and baby food, Prepare food, Cook food with waterIf the concentration of arsenic in your well exceeds 0.010 mg/Lhigh
#Q004operationalhealthguidancePermitted tap water uses during exceedancesdrinking waterYou can use tap water to: Wash food, Steam food, Wash dishes and clothes, Take a shower or bathIf the concentration of arsenic in your well exceeds 0.010 mg/Lhigh
#Q005prohibitionhealthguidanceBoiling water warningdrinking waterBoiling water is pointless because arsenic does not evaporate. In fact, doing so can increase the concentration of arsenic in the water.high
#Q006treatmenttreatmentguidanceTreatment system installation guidancedrinking waterYou can install a residential water treatment system to reduce the concentration of arsenic in water to an acceptable level.When reducing arsenic concentration.high
#Q007treatmenttreatmentrecommendedTreatment system certification and maintenancedrinking waterBe sure to install a certified system that conforms to NSF/ANSI standards and follow the manufacturer’s maintenance recommendations.If installing a residential water treatment system.high
#Q008monitoringtreatmentmandatoryTreatment system verification testingdrinking waterIf you install a residential water treatment system to eliminate barium from your water, you must verify its effectiveness by testing your water every year.If you install a residential water treatment system (note: text explicitly mentions barium in this arsenic document).high

P Quantitative Requirements (3)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001chemicalhealthmandatoryArsenicdrinking waterMAC<= 0.010 mg/LBy Québec standards, the concentration of arsenic in drinking water should not exceed 0.010 mg/l. Considering that arsenic can have serious effects on health, its concentration in drinking water should always be as low as possible.high
#P002operationalhealthrecommendedArsenic well testing frequencydrinking waterrequirement>= 1 test/well-usage-periodIdeally in the spring or fall.During the period of usage of the well.high
#P003operationaloperationalmandatoryTreatment system verification frequency (Barium)drinking waterrequirement1 test/yearIf you install a residential water treatment system to eliminate barium from your water, you must verify its effectiveness by testing your water every year.Applies if a residential water treatment system is installed to eliminate barium.high

D Definitions (0)

No definitions.