Document ID ca-mpppler-1977 Title Meat and Poultry Products Plant Liquid Effluent Regulations URL https://ccme.ca/en/summary-table Jurisdiction /ca Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:38:55.132395+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (17)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativeunknownguidanceGuideline Implementation Consultationaquatic life, agricultural water, otherUsers are advised to consult the Canadian Environmental Quality Guidelines introductory text, factsheet, and/or protocols for specific information and implementation guidance pertaining to each environmental quality guideline.high
#Q002designoperationalmandatoryEffluent Monitoring Facility InstallationwastewaterThe owner of a plant shall, for each type of effluent deposited by the plant, install and maintain facilities, including sampling connections and flow measuring devices, of such type as the Minister may in writing approve for sampling and analysing effluents for the purpose of enabling the Minister to determine whether the owner is complying with the limits of authorized deposits prescribed by section 5;Applies for each type of effluent deposited by the plant.high
#Q003monitoringoperationalmandatoryCompliance with Standard Methods for Sampling and StoragewastewaterFor the purposes of paragraph 6(c), procedures pertaining to sampling, preservation and storage of samples and prevention of interference relating to the test methods referred to in paragraph (1)(a), as outlined in the general sections of the publication Standard Methods for the Examination of Water and Wastewater, 14th Edition (1975), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation, shall be adhered to.Applies to composite samples analyzed under section 9.high
#Q004reportingreportingmandatoryMonthly Effluent ReportingwastewaterThe owner of a plant shall, within 30 days after the end of each equivalent month, sign, date and forward to the Minister a report, in such form as the Minister may in writing approve, showing for that equivalent month [actual daily deposits, average daily deposits, pH, production, operating days, daily flow, and ammonia nitrogen].Within 30 days after the end of each equivalent month.high
#Q005prohibitionoperationalmandatoryProhibition of Test Sample Chemical Adjustmentaquatic lifethere shall be no direct adjustment of the pH or other chemical characteristics of the test sample;Applies to the conduct of the 96-hour acute lethality static test using rainbow trout.high
#Q006reportingreportingmandatoryAnnual Production DeclarationwastewaterThe owner of a plant shall, within 30 days after the end of each calendar year, sign, date and forward to the Minister a declaration in such form as the Minister may in writing approve, showing the actual production of the plant for the previous year, in terms of tonnes of finished product for integrated and processing plants and tonnes of raw material for rendering plants and declaring equivalent months for the forthcoming year.Within 30 days after the end of each calendar year.high
#Q007monitoringoperationalmandatoryComposite Sampling MethodologywastewaterA composite sample shall be obtained by collecting effluent discharged from a plant during an operating day (a) continually during a sampling period of 24 hours at a rate in proportion to the flow rate of the effluent discharged; or (b) in such a manner that equal volumes of effluent are delivered into a receptacle at equal intervals not longer than one hour during a sampling period of 24 hours.Standard operating days for all plants unless sub-sections 7(2) or 7(3) apply.high
#Q008monitoringoperationalmandatoryContinuous Flow MeasurementwastewaterSubject to subsection (2), for the purpose of paragraph 6(d), the flow of each type of effluent deposited by a plant shall be measured and recorded continuously.Applies unless specific plant production sizes allow alternative measurement under 10(2).high
#Q009reportingreportingmandatoryInitial Plant Status DeclarationwastewaterThe owner of a new plant shall, before he deposits any deleterious substance prescribed by section 4, and the owner of an expanded plant shall, within 30 days of becoming subject to these Regulations, sign, date and forward to the Minister a declaration, in such form as the Minister may in writing approve, showing whether the plant is an integrated plant, processing plant or rendering plant; showing whether the plant will process red meat or poultry or both; showing the projected annual production of the plant; and declaring equivalent months for the remainder of the calendar year.Applies to new plants before deposit or expanded plants within 30 days of being subject to regulations.high
#Q010monitoringoperationalmandatoryLethality Test Sample Preservationaquatic lifewhen transportation or storage of a composite sample is necessary, special precautions shall be used to minimize degradation as follows: (i) the sample shall be kept in sealed containers which are completely filled to the exclusion of all air, (ii) if it is necessary for the sample to be stored more than 60 hours between collection and testing, the sample shall be brought to a temperature range of 1° to 6 °C as soon as possible after collection and maintained at this temperature range until just prior to being tested, and (iii) acute lethality testing shall commence as soon as possible but in no case shall it commence later than four days after sampling.When transportation or storage of a composite sample for acute lethality testing is necessary.high
#Q011monitoringoperationalmandatoryMandatory Composite Sampling DutywastewaterThe owner of a plant shall, for each type of effluent deposited by the plant... take a composite sample on the regular basis prescribed by section 8;high
#Q012monitoringoperationalmandatoryMandatory Acute Lethality Testing Dutyaquatic lifeThe owner of a plant shall, for each type of effluent deposited by the plant... conduct the acute lethality test on a composite sample from a plant referred to in Column I of Schedule II at the frequency set out opposite that plant in Column II thereof.Applies to plants listed in Schedule II.high
#Q013prohibitionhealthmandatoryProhibition of Throwing Deleterious Substances Overboardaquatic lifeNo one shall (a) throw overboard ballast, coal ashes, stones or other prejudicial or deleterious substances in any river, harbour or roadstead, or in any water where fishing is carried on;Applies in any river, harbour, roadstead, or water where fishing is carried on.high
#Q014prohibitionaestheticmandatoryProhibition of Depositing Fish or Marine Animal Remains on Shoreaquatic life, otherNo one shall (b) leave or deposit or cause to be thrown, left or deposited, on the shore, beach or bank of any water or on the beach between high and low water mark, remains or offal of fish or of marine animals;Applies to shores, beaches, or banks of any water.high
#Q015prohibitionhealthmandatoryProhibition of Leaving Decaying Fish in Fishing Apparatusaquatic lifeNo one shall (c) leave decayed or decaying fish in any net or other fishing apparatus.high
#Q016prohibitionhealthmandatoryGeneral Prohibition of Depositing Deleterious Substancesaquatic lifeSubject to subsection (4), no person shall deposit or permit the deposit of a deleterious substance of any type in water frequented by fish or in any place under any conditions where the deleterious substance or any other deleterious substance that results from the deposit of the deleterious substance may enter any such water.Applies to water frequented by fish or places where substances may enter such water.high
#Q017monitoringreportingmandatoryMandatory Monitoring and Reporting under Ministerial Directionwastewater, aquatic lifeA person authorized to deposit a deleterious substance by or under regulations made under subsection (5) or (5.2) shall, when directed by the Minister... conduct any sampling, analyses, tests, measurements or monitoring, install or operate any equipment or comply with any procedures, and report any information, that is required by the Minister in order to determine whether the person is depositing the deleterious substance in the manner authorized.Applies when directed by the Minister to a person authorized to deposit substances under regulation.high

P Quantitative Requirements (56)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#R001physicaloperationalmandatorypH Rangewastewaterrequirement6.0 - 9.0 pH unitspH of each composite sample of effluentPrior to authorized deposithigh
#R002chemicaloperationalmandatoryAuthorized Actual Daily Deposit - BOD (Red Meat Integrated Plant)wastewaterrequirement<= 1.0 kg/tonne of finished productRed Meat Integrated Plant actual daily depositDetermined in accordance with subsection 11(1)high
#R003chemicaloperationalmandatoryAuthorized Average Daily Deposit - BOD (Red Meat Integrated Plant)wastewaterrequirement<= 0.5 kg/tonne of finished productRed Meat Integrated Plant average daily deposit during an equivalent monthDetermined in accordance with subsection 11(2)high
#R004chemicaloperationalmandatoryStorm Water Exclusion BOD Thresholdwastewaterrequirement<= 50 mg/LAverage concentration of biochemical oxygen demanding matter in at least 3 samples of storm waterTaken at intervals of 15 minuteshigh
#R005physicaloperationalmandatoryAcute Lethality Test Dissolved Oxygenwastewaterrequirement>= 8 mg/lMinimum dissolved oxygen level maintained during testAeration or oxygenation minimized to reduce stripping of volatile compoundshigh
#R006physicaloperationalmandatoryAcute Lethality Test Temperaturewastewaterrequirement15 ± 1 CelsiusTemperature at which the test is conductedhigh
#R007physicaloperationalmandatoryTest Sample Storage Temperaturewastewaterrequirement1 - 6 CelsiusSample brought to and maintained at this range if stored more than 60 hoursNecessary storage between collection and testinghigh
#R008chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Total Suspended Matter (Red Meat Integrated Plant)wastewaterrequirement<= 1.2 kg/tonne of finished productRed Meat Integrated Plant actual daily deposit of total suspended matterDetermined in accordance with subsection 11(1)high
#R009chemicaloperationalmandatoryAuthorized Average Daily Deposit - Total Suspended Matter (Red Meat Integrated Plant)wastewaterrequirement<= 0.6 kg/tonne of finished productRed Meat Integrated Plant average daily deposit of total suspended matter during an equivalent monthDetermined in accordance with subsection 11(2)high
#R010chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Grease (Red Meat Integrated Plant)wastewaterrequirement<= 1.6 kg/tonne of finished productRed Meat Integrated Plant actual daily deposit of greaseDetermined in accordance with subsection 11(1)high
#R011chemicaloperationalmandatoryAuthorized Average Daily Deposit - Grease (Red Meat Integrated Plant)wastewaterrequirement<= 0.8 kg/tonne of finished productRed Meat Integrated Plant average daily deposit of grease during an equivalent monthDetermined in accordance with subsection 11(2)high
#R012chemicaloperationalmandatoryAuthorized Actual Daily Deposit - BOD (Processing Plant)wastewaterrequirement<= 0.7 kg/tonne of finished productProcessing Plant actual daily deposit of BODDetermined in accordance with subsection 11(1)high
#R013chemicaloperationalmandatoryAuthorized Average Daily Deposit - BOD (Processing Plant)wastewaterrequirement<= 0.35 kg/tonne of finished productProcessing Plant average daily deposit of BOD during an equivalent monthDetermined in accordance with subsection 11(2)high
#R014chemicaloperationalmandatoryAuthorized Actual Daily Deposit - TSM (Processing Plant)wastewaterrequirement<= 0.5 kg/tonne of finished productProcessing Plant actual daily deposit of total suspended matterDetermined in accordance with subsection 11(1)high
#R015chemicaloperationalmandatoryAuthorized Average Daily Deposit - TSM (Processing Plant)wastewaterrequirement<= 0.25 kg/tonne of finished productProcessing Plant average daily deposit of total suspended matter during an equivalent monthDetermined in accordance with subsection 11(2)high
#R016chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Grease (Processing Plant)wastewaterrequirement<= 0.8 kg/tonne of finished productProcessing Plant actual daily deposit of greaseDetermined in accordance with subsection 11(1)high
#R017chemicaloperationalmandatoryAuthorized Average Daily Deposit - Grease (Processing Plant)wastewaterrequirement<= 0.4 kg/tonne of finished productProcessing Plant average daily deposit of grease during an equivalent monthDetermined in accordance with subsection 11(2)high
#R018chemicaloperationalmandatoryAuthorized Actual Daily Deposit - BOD (Poultry Integrated Plant)wastewaterrequirement<= 1.4 kg/tonne of finished productPoultry Integrated Plant actual daily deposit of BODDetermined in accordance with subsection 11(1)high
#R019chemicaloperationalmandatoryAuthorized Average Daily Deposit - BOD (Poultry Integrated Plant)wastewaterrequirement<= 0.7 kg/tonne of finished productPoultry Integrated Plant average daily deposit of BOD during an equivalent monthDetermined in accordance with subsection 11(2)high
#R020chemicaloperationalmandatoryAuthorized Actual Daily Deposit - TSM (Poultry Integrated Plant)wastewaterrequirement<= 1.0 kg/tonne of finished productPoultry Integrated Plant actual daily deposit of total suspended matterDetermined in accordance with subsection 11(1)high
#R021chemicaloperationalmandatoryAuthorized Average Daily Deposit - TSM (Poultry Integrated Plant)wastewaterrequirement<= 0.5 kg/tonne of finished productPoultry Integrated Plant average daily deposit of total suspended matter during an equivalent monthDetermined in accordance with subsection 11(2)high
#R022chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Grease (Poultry Integrated Plant)wastewaterrequirement<= 1.0 kg/tonne of finished productPoultry Integrated Plant actual daily deposit of greaseDetermined in accordance with subsection 11(1)high
#R023chemicaloperationalmandatoryAuthorized Average Daily Deposit - Grease (Poultry Integrated Plant)wastewaterrequirement<= 0.5 kg/tonne of finished productPoultry Integrated Plant average daily deposit of grease during an equivalent monthDetermined in accordance with subsection 11(2)high
#R024chemicaloperationalmandatoryAuthorized Actual Daily Deposit - BOD (Rendering Plant)wastewaterrequirement<= 0.4 kg/tonne of raw materialRendering Plant actual daily deposit of BODDetermined in accordance with subsection 11(1)high
#R025chemicaloperationalmandatoryAuthorized Average Daily Deposit - BOD (Rendering Plant)wastewaterrequirement<= 0.2 kg/tonne of raw materialRendering Plant average daily deposit of BOD during an equivalent monthDetermined in accordance with subsection 11(2)high
#R026microbiologicaloperationalmandatoryAcute Lethality Control Mortality Limitwastewaterrequirement<= 10 per centMaximum death rate of control fish for a valid testExposure over 96 hourshigh
#R027physicaloperationalmandatoryAcute Lethality Sample Volume Ratiowastewaterrequirement>= 1.5 litres per gram of fishMinimum volume of fresh test sample per 96-hour testhigh
#R028designoperationalmandatoryAcute Lethality Minimum Water Depthwastewaterrequirement>= 10 cmMinimum water depth in any test vesselhigh
#R029physicaloperationalmandatoryAcute Lethality Fish Weight Rangewastewaterrequirement0.5 - 10 gramsWeight range for individual fish used in the testWeight of largest fish not more than twice the smallesthigh
#R030chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Total Suspended Matter (Rendering Plant)wastewaterrequirement<= 0.4 kg/tonne of raw materialRendering Plant actual daily deposit of total suspended matterDetermined in accordance with subsection 11(1)high
#R031chemicaloperationalmandatoryAuthorized Average Daily Deposit - Total Suspended Matter (Rendering Plant)wastewaterrequirement<= 0.2 kg/tonne of raw materialRendering Plant average daily deposit of total suspended matter during an equivalent monthDetermined in accordance with subsection 11(2)high
#R032chemicaloperationalmandatoryAuthorized Actual Daily Deposit - Grease (Rendering Plant)wastewaterrequirement<= 0.3 kg/tonne of raw materialRendering Plant actual daily deposit of greaseDetermined in accordance with subsection 11(1)high
#R033chemicaloperationalmandatoryAuthorized Average Daily Deposit - Grease (Rendering Plant)wastewaterrequirement<= 0.15 kg/tonne of raw materialRendering Plant average daily deposit of grease during an equivalent monthDetermined in accordance with subsection 11(2)high
#R034physicaloperationalmandatoryTreated Wastewater Exclusion pH Limitwastewaterrequirement6.0 - 9.0 pH unitspH of wastewater treated at a site outside a plant to be excluded from 'effluent' definitionDetermined in accordance with subsection 9(3)high
#R035physicaloperationalmandatoryMaximum Aeration Time Before Lethality Testwastewaterrequirement<= 2 hoursAeration or oxygenation of the test sample prior to the commencement of the testRequired to maintain minimum dissolved oxygen levelhigh
#R036physicaloperationalmandatoryAcute Lethality Test Sample Storage Refrigeration Thresholdwastewaterrequirement> 60 hoursStorage duration trigger requiring sample cooling to 1-6 °CNecessary storage between collection and testinghigh
#R037physicaloperationalmandatoryAcute Lethality Test Commencement Deadlinewastewaterrequirement<= 4 daysMaximum allowable time between sampling and commencement of acute lethality testinghigh
#R038operationaloperationalmandatoryMinimum Composite Sample Volumeswastewaterrequirement>= 4 equal volumesFor red meat/poultry/processing plants under production thresholdsDelivered into a receptacle at equal intervalshigh
#R039operationaloperationalmandatoryMinimum Composite Sampling Durationwastewaterrequirement>= 4 hoursSampling period during which slaughtering or processing is performedFor plants under specific production thresholdshigh
#R040operationaloperationalmandatoryAcute Lethality Test Subject Countwastewaterrequirement>= 10 fishNumber of fish exposed to a representative portion of the composite sampleAn equal number shall be exposed as control fishhigh
#R041operationaloperationalmandatoryAcute Lethality Test Durationwastewaterrequirement96 hoursExposure period for fish in the lethality testIdentical conditions for test and control groupshigh
#R042operationaloperationalmandatoryAcute Lethality Fish Weight Variance Ratiowastewaterrequirement<= 2 ratioWeight of the largest fish compared to the smallestIndividual fish must weigh between 0.5 and 10 gramshigh
#R043operationalreportingmandatoryMonthly Reporting Deadlinewastewaterrequirement<= 30 daysTimeframe to forward report to the Minister after the end of each equivalent monthMust include all sampling results and flow datahigh
#R044operationaloperationalmandatoryExpanded Plant Production Thresholdwastewaterrequirement> 2.5 times average annual amountDefinition of an expanded plant based on production increases compared to historical averagesApplies to cases where production exceeds 2.5 times the 1971-1975 or start-to-1977 averagehigh
#R045operationaloperationalmandatoryStandard Composite Sample Durationwastewaterrequirement24 hoursDuration of effluent collection for a standard composite sampleDuring an operating dayhigh
#R046operationaloperationalmandatoryStandard Composite Sample Intervalwastewaterrequirement<= 1 hourMaximum interval between delivery of equal volumes into a receptacle for a composite sampleDuring a 24-hour sampling periodhigh
#R047operationaloperationalmandatorySampling Frequency - Low Volume Plantswastewaterrequirement1 per equivalent monthSampling frequency for small integrated/processing plantsRed meat/processing < 500 tonnes, poultry < 2 500 tonnes annuallyhigh
#R048operationaloperationalmandatorySampling Frequency - Standard Volume Plantswastewaterrequirement1 per weekSampling frequency for medium integrated plants and all rendering plantsIncludes red meat 500-10,000 tonnes and poultry 2,500-7,000 tonnes annuallyhigh
#R049operationaloperationalmandatorySampling Frequency - High Volume Plantswastewaterrequirement2 per weekSampling frequency for large integrated plantsRed meat > 10,000 tonnes, poultry > 7,000 tonnes annuallyhigh
#R050operationalreportingmandatoryNew or Expanded Plant Declaration Deadlinewastewaterrequirement30 daysDeadline to forward a declaration for an expanded plantWithin 30 days of becoming subject to the Regulationshigh
#R051operationalreportingmandatoryAnnual Production Declaration Deadlinewastewaterrequirement30 daysDeadline for annual declaration of actual production and future equivalent monthsAfter the end of each calendar yearhigh
#R052operationaloperationalmandatoryAcute Lethality Testing Frequency - Low Volume Plantswastewaterrequirement1 per calendar yearSampling frequency for small integrated/processing plants for toxicity testingRed meat/processing < 500 tonnes, poultry < 2 500 tonnes annuallyhigh
#R053operationaloperationalmandatoryAcute Lethality Testing Frequency - Standard Rendering/Integratedwastewaterrequirement1 per 13 week periodToxicity testing frequency for high volume or rendering plantsIntervals greater than one calendar monthhigh
#R054operationaloperationalmandatoryEquivalent Month Duration Rangewastewaterrequirement4 - 6 weeksDuration of a period declared as an equivalent month for compliance purposeshigh
#R055operationaloperationalmandatoryAcute Lethality Testing Frequency - Mid-Volume Plantswastewaterrequirement2 per calendar yearSampling frequency for acute lethality testing in mid-sized facilitiesAt intervals greater than four calendar months; applies to Red Meat (500-10,000 t), Processing (>500 t), and Poultry (2,500-7,000 t)high
#R056operationaloperationalmandatoryAcute Lethality Observation Intervalswastewaterrequirement1/4, 1/2, 1, 2, 4, 8, 24, 48, 72, 96 hoursSpecific intervals at which the number of dead fish must be recorded during the 96-hour testRecorded for both treatment and control vesselshigh

D Definitions (47)

Req ID Category Name Context Confidence
#D001major modificationA major modification is one that requires a change in the licensing basis for the facility or activity.high
#D002action levelAn action level is defined as a specific dose of radiation or other parameter that, if reached, may indicate a loss of control of part of a licensee’s radiation protection program or environmental protection program, and triggers a requirement for specific action to be taken.high
#D003interim periodThe interim period is the time from when adaptive management is triggered through to completion of commissioning of the new treatment system or other control measures.high
#D004Exemption Quantity (EQ)As specified in the Nuclear Substances and Radiation Devices Regulationshigh
#D005Unconditional Clearance Levels (UCLs)As specified in the Nuclear Substances and Radiation Devices Regulationshigh
#D006Practice-specific CCLsEstablished by the CNSC for a specific industrial facility/activityhigh
#D007BATEAthe term BATEA is used when referring to both nuclear and hazardous substances [representing best available technology and techniques economically achievable]high
#D008ALARAthe term ALARA is used when referring solely to nuclear substances [representing as low as reasonably achievable]high
#D009licensed limitA licensed limit is part of the licensing basis and, if exceeded, represents a loss of control of part of the licensee’s program(s) or control measure(s).high
#D010licensed release limitsLicensed release limits are a subset of licensed limits, that are specific to releases to the environment, and are part of the licensing basis.high
#D011environmental release targets (ERTs)evaluation criteria used as the basis of the design of the treatment technologies and techniques being appraised as part of the BATEA assessment.high
#D012Adaptive managementAdaptive management involves, among other things, the implementation of new or modified mitigation measures over the life of a project to address unanticipated environmental effects.high
#D013Generic CCLsAs specified in table A.1 of this appendixhigh
#D014ExclusionExclusion is for sources/exposures where it is impossible to exert control over them.high
#D015ExemptionExemption is for sources/exposures where control is potentially feasible, but it is considered unnecessary or unwarranted, and a decision is made a priori to exempt it from regulatory controlhigh
#D016ClearanceClearance can be thought of as exemption from within where it serves as permission for the materials developed or arising from a regulated activity to exit the regulatory system with no further regulatory requirements or oversighthigh
#D017Authorization for dischargeallows the release (that is, discharge to the environment) of the substance while continuing to maintain regulatory control and oversight of the release through the maintenance of additional regulatory requirementshigh
#D018maximum predicted design release characteristics (MPDRCs)the proposed location of the points of release, the proposed maximum quantities and concentrations, and the anticipated volume and flow rate of nuclear and hazardous substances expected to be released to the environment, including their physical, chemical and radiological characteristics.high
#D019Public dose constraintsestimates of public dose, less than the regulatory public dose limit, that are either established or approved by the CNSC for use in the optimization process.high
#D020residual releasethe remaining release of a nuclear or hazardous substance, after accounting for all treatment and mitigation through the application of BATEA.high
#D021EMSenvironmental management systemhigh
#D022PSRperiodic safety reviewhigh
#D023WTPwastewater treatment planthigh
#D024POIpoint-of-impingementhigh
#D025upper value of normal operationbased on the predicted or current operating conditions, and is typically determined using either: a prospective approach for a new facility or activity, based on the approved design and other relevant information; a retrospective approach for an existing facility or activity, using all available performance data (including historical data)high
#D026ERAenvironmental risk assessmenthigh
#D027IPPPinterim pollution prevention planhigh
#D028SATsite acceptance testinghigh
#D029FATfactory acceptance testinghigh
#D030SOPsstandard operating procedureshigh
#D031OHSoccupational health and safetyhigh
#D032dilution zonespatial extent of the initial mixing zonehigh
#D033shallused to express requirements to be satisfied by the licensee or licence applicant.high
#D034mustused to express requirements to be satisfied by the licensee or licence applicant.high
#D035shouldused to express guidance or that which is advised.high
#D036mayused to express an option or that which is permissible within the limits of this regulatory document.high
#D037canused to express possibility or capability.high
#D038NSCANuclear Safety and Control Acthigh
#D039CCLsconditional clearance levelshigh
#D040IAEAInternational Atomic Energy Agencyhigh
#D041QA/QCquality assurance and quality controlhigh
#D042NSRDRNuclear Substances and Radiation Devices Regulationshigh
#D043GNSCRGeneral Nuclear and Safety Control Regulationshigh
#D044CNSCCanadian Nuclear Safety Commissionhigh
#D045CCMECanadian Council of Ministers of the Environmenthigh
#D046FdDilution factorhigh