Parameter Viewer

Document ID ca-on-toronto-mtdsf-5 Title Manufactured Treatment Device Summary Form URL https://www.toronto.ca/wp-content/uploads/2025/06/95e2-drinking-water-analysis-summary-2024.pdf Jurisdiction /ca/on/toronto Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:30:40.110466+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (37)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001monitoringoperationalmandatoryMicrobiological Analysis Method for Resamplesdrinking waterMicrobiological analysis for resamples and vicinities is conducted using the Membrane Filtration technique.Applies to resamples and vicinitieshigh
#Q002reportingreportingmandatoryCalculation Methodology for Component Sumsdrinking waterWhere standards are based on sums of components, the following calculations are used: - Atrazine + N-dealkylated metabolites = Atrazine + Desethylatrazine - HAA5 (total) = Bromoacetic acid + Chloroacetic acid + Dibromoacetic acid + Dichloroacetic acid + Trichloroacetic acid - PCB total = Arochlor 1232 + 1242 + 1248 + 1254 + 1260 + 1262 - THM (total) = Bromodichloromethane + Bromoform + Chloroform + Dibromochloromethane - Xylenes (total) = m- & p-Xylene + o-XyleneWhere standards are based on sums of componentshigh
#Q003reportingreportingmandatoryReporting of Below Limit Resultsdrinking waterAll results below Reporting limit are recorded as zero in this summaryWhen results are below the Reporting limithigh
#Q004reportingreportingmandatoryBWRF Submission Mandatory RequirementotherThe purpose of this work instruction is to establish common understanding and achieving harmonization in the Canadian Ballast Water Reporting Form (BWRF) completion which must be submitted by the master of a vessel that is bound for a port, offshore terminal, or anchorage area in Canada to Transport Canada Marine Safety and Security (TCMSS) in accordance with the Ballast Water Regulations (The Regulations).Vessel bound for a port, offshore terminal, or anchorage area in Canadahigh
#Q005administrativereportingmandatoryCurrent BWRF Version RequirementotherTo fully comply with all reporting requirements, vessel’s master must use the current version of the Canadian BWRF available at the time of the submission.high
#Q006administrativeoperationalmandatorySubmission Format - Active PDFotherThe BWRF shall be sent as an “Active” PDF using “save” or “ save as” file options to enable data entry software.high
#Q007prohibitionreportingmandatoryProhibition of Scanned FormsotherForms which have been “scanned” and then attached will NOT be accepted.high
#Q008prohibitionreportingmandatoryProhibition of Printed to PDF FormsotherForms “Printed to PDF “will NOT be accepted.high
#Q009reportingreportingmandatoryComplete Field Entry RequirementotherAll fields shall be filled in, even if the values are zero or NA.high
#Q010monitoringoperationalmandatoryBallast Tank Data RecordingotherThe dates and sources of ALL ballast tanks are to be recorded whether empty, having residuals or ballasted.high
#Q011reportingreportingmandatorySubmission of Amended FormsotherAmended forms are to be submitted if there are any changes to the original ballast water reporting form.If there are any changes to the original ballast water reporting form (e.g., Arrival Date, Arrival Port, or planned discharge)high
#Q012reportingreportingmandatoryFlag State Entry RequirementotherEnter the full name of the State or territory whose flag the vessel is flying at the moment of the BWRF submission. No abbreviations will be accepted.high
#Q013reportingoperationalmandatoryBallast Water History Recording RequirementotherRecord information for all ballast tanks/holds regardless of ballast water management intentions in the section 5 tables (Ballast Water sources are the most recent uptakes prior to any ballast water management practices).high
#Q014reportingreportingmandatoryPort Naming and Abbreviation ProhibitionotherAll “port” fields should contain only the name of the port and not the country. No abbreviations shall be used. If the port is entered, the proper UNLOCODE shall be used as a preferred approach.When entering arrival, last, next, and discharge portshigh
#Q015reportingreportingmandatoryStandard Date Format RequirementotherAll dates shall be entered in the format of yyyy-mm-dd (separating year, month and date by a “- “).Applicable to all date entries in the BWRFhigh
#Q016reportingreportingmandatoryVolume Unit RequirementotherVolume to be recorded should be in cubic meters (m3) only.Applicable to total ballast water on board and total capacity reportinghigh
#Q017administrativereportingmandatoryFillable Fields and Re-submission RequirementotherOnly data contained in “Fillable Fields” is accepted, “Non-Editable” forms cannot be accepted by TCMSS therefore the vessel will be required to re-submit as an “Active” PDF.When submitting BWRF datahigh
#Q018reportingreportingmandatoryMaster's Electronic Submission DutyotherOnce the BWRF is completed by the Master, an electronic copy is to be forwarded to TCMSS in the manner described in the Ship Safety Bulletin #07/2022.high
#Q019reportingreportingmandatoryTime of Submission FormatotherEnter the time that the report will be sent (UTC) using the 24-hour clock format.high
#Q020prohibitionreportingmandatoryVessel Naming ConventionotherEnter the name of the vessel. In case of tug and barge operation (pull, push, sideway or an articulated tug and Barge), please enter both vessel names, separated by a hyphen (-) . Do not add additional extension such as “M/V” (Motor Vessel), “M/S” (Motor Ship) or “T/S” (Tanker Ship / Tall Ship).Tug and barge operations and vessel name entryhigh
#Q021reportingreportingmandatoryLast Survey N/A EntryotherShould none of these has been performed “N/A” must be recorded under this item.If no last survey or endorsement has been performedhigh
#Q022reportingoperationalmandatoryTank Identification and CodesotherList all ballast water tanks and holds separately (e.g., port and starboard tanks should be on separate rows), use tank codes: FP=Forepeak; DB=Double bottom; WT=Wing tank; TS=Topside; AP=Aftpeak; CH=Cargo hold; O = Other).high
#Q023reportingreportingmandatoryCoordinate FormattingotherAll position (latitude and longitude) shall be entered in the format: 00 00 N or 00 00 S; Longitude (examples: 000 00 W or 000 00 E). Latitude (examples: 56 32 N or 56 32 S); Longitude examples: 016 25 W or 159 42 E must be used.high
#Q024reportingreportingmandatoryGross Tonnage Decimal ProhibitionotherGross tonnage: Enter the gross tonnage of the vessel as established under the International Convention on Tonnage Measurement of Ships, 1969 or any successor Convention. No decimals.high
#Q025reportingreportingmandatoryMandatory State/Province AbbreviationsotherAbbreviations to be used are as follows: British Columbia – BC; Illinois – IL; Indiana – IN; Michigan – MI; Minnesota – MN; New Brunswick – NB; New York – NY; Newfoundland – NL; Northwest Territories – NT; Nova Scotia – NS; Nunavut – NU; Ohio – OH; Ontario – ON; Pennsylvania – PA; Prince Edward Island – PE, Quebec –QC; Washington - WA; Wisconsin – WI; Yukon – YT.When selecting the name of the Canadian province, territory, or U.S. state for the arrival porthigh
#Q026prohibitionreportingmandatoryProhibition of Vague Discharge Volume DescriptionsotherVolume (m3) (Column 17): Report the expected volume of ballast water to be discharged in cubic meters. Do not enter “Depends on cargo operations” or similar statements.high
#Q027reportingreportingmandatoryReporting Non-Operational BWMS IssuesotherCheck “No” if there was a known issue with the treatment of ballast water currently carried on board and describe the issue.If the Ballast Water Management System was not fully operational during managementhigh
#Q028reportingoperationalmandatoryResidual Ballast Exclusion for Tank CountsotherDo not include ballast tanks carrying only residual ballast water or sediment.When entering number of tanks in ballasthigh
#Q029reportingoperationalmandatoryResidual Ballast Exclusion for Hold CountsotherDo not include cargo holds carrying only residual ballast water or sediment.When entering number of holds in ballasthigh
#Q030reportingreportingmandatoryMandatory D-2 Date EntryotherFill all fields – especially taking care to fill out the field with the “Date required to meet Regulations D-2” as established under the Convention or the Regulations, as applicable.high
#Q031reportingreportingmandatoryReason for Unmanaged BallastotherState the reason why no ballast water management was conducted: This applies to all tanks and cargo holds that have not been exchanged or treated using an IMO approved BWMS and are intended to be discharged into waters under Canadian jurisdiction or into an approved reception facility or another vessel.Applies to unmanaged tanks intended for dischargehigh
#Q032reportingreportingmandatoryConditional Discharge ReportingotherComplete columns under the general heading of “Proposed BW Discharge” only if de-ballasting will take place in waters under Canadian jurisdiction.De-ballasting in Canadian jurisdictionhigh
#Q033monitoringoperationalguidanceSalinity Determination GuidanceotherIf the vessel does NOT have a refractometer on board to determine the salinity, tables converting specific gravity to salinity are available for download at the following NOAA link: https://greatlakes-seaway.com/wp-content/uploads/2019/10/NOAA_conversion_table_tm-1391.pdfVessel lacks refractometerhigh
#Q034monitoringoperationalmandatoryMicrobiological Presence-Absence Sampling Scopedrinking waterMicrobiological Presence-Absence (P/A) samples include treated water samples from the Water Treatment Plants, Distribution samples, as well as samples collected after Water main repair work and Water Quality InquiryApplies to treated water, distribution, and repair-related sampleshigh
#Q035monitoringoperationalmandatoryMicrobiological Analysis Method for Resamplesdrinking waterMicrobiological analysis for resamples and vicinities is conducted using the Membrane Filtration technique.Applies to resamples and vicinitieshigh
#Q036reportingreportingmandatoryCalculation Methodology for Component Sumsdrinking waterWhere standards are based on sums of components, the following calculations are used: - Atrazine + N-dealkylated metabolites = Atrazine + Desethylatrazine - HAA5 (total) = Bromoacetic acid + Chloroacetic acid + Dibromoacetic acid + Dichloroacetic acid + Trichloroacetic acid - PCB total = Arochlor 1232 + 1242 + 1248 + 1254 + 1260 + 1262 - THM (total) = Bromodichloromethane + Bromoform + Chloroform + Dibromochloromethane - Xylenes (total) = m- & p-Xylene + o-XyleneWhere standards are based on sums of componentshigh
#Q037reportingreportingmandatoryReporting of Below Limit Resultsdrinking waterAll results below Reporting limit are recorded as zero in this summaryWhen results are below the reporting limithigh

P Quantitative Requirements (44)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001chemicalhealthmandatoryMicrocystindrinking waterMAC1.5 µg/LDrinking Water Analysis SUMMARY 2024high
#P002chemicalhealthmandatoryFluoridedrinking waterMAC1.5 mg/LOperational Parametershigh
#P003chemicaltreatmentmandatoryTotal Chlorine residual (Chloramines)drinking waterMAC3.0 mg/LOperational Parametershigh
#P004chemicalaestheticguidelineHardness ( as CaCO3 - calculated )drinking waterAO80-100 mg/LGeneral Chemical and Physical Parametershigh
#P005physicalaestheticguidelinepHdrinking waterAO6.5-8.5 nullGeneral Chemical and Physical Parametershigh
#P006chemicalhealthmandatoryAntimonydrinking waterMAC0.006 mg/LInorganic Parametershigh
#P007chemicalhealthmandatoryArsenicdrinking waterMAC0.01 mg/LInorganic Parametershigh
#P008chemicalhealthmandatoryBariumdrinking waterMAC1.0 mg/LInorganic Parametershigh
#P009chemicalhealthmandatoryBorondrinking waterMAC5.0 mg/LInorganic Parametershigh
#P010chemicalhealthmandatoryCadmiumdrinking waterMAC0.005 mg/LInorganic Parametershigh
#P011chemicalhealthmandatoryChromiumdrinking waterMAC0.05 mg/LInorganic Parametershigh
#P012chemicalaestheticguidelineCopperdrinking waterAO1 mg/LInorganic Parametershigh
#P013chemicalhealthmandatoryCyanide (Free)drinking waterMAC0.2 mg/LInorganic Parametershigh
#P014chemicalaestheticguidelineIrondrinking waterAO0.3 mg/LInorganic Parametershigh
#P015chemicalhealthmandatoryLeaddrinking waterMAC0.01 mg/LInorganic Parametershigh
#P016chemicalaestheticguidelineManganesedrinking waterAO0.05 mg/LInorganic Parametershigh
#P017chemicalhealthmandatoryMercurydrinking waterMAC0.001 mg/LInorganic Parametershigh
#P018chemicalhealthmandatoryNitratedrinking waterMAC10 mg/LInorganic Parametershigh
#P019chemicalhealthmandatoryNitritedrinking waterMAC1 mg/LInorganic Parametershigh
#P020chemicalhealthmandatorySeleniumdrinking waterMAC0.05 mg/LInorganic Parametershigh
#P021chemicalaestheticguidelineSodiumdrinking waterAO200 mg/LInorganic Parametershigh
#P022chemicalaestheticguidelineSulphatedrinking waterAO500 mg/LInorganic Parametershigh
#P023chemicalhealthmandatoryUraniumdrinking waterMAC0.02 mg/LInorganic Parametershigh
#P024chemicalaestheticguidelineZincdrinking waterAO5 mg/LInorganic Parametershigh
#P025chemicalhealthmandatoryTHM (total)drinking waterMAC100 µg/LDisinfection Byproducts- Trihalomethaneshigh
#P026chemicalhealthmandatoryHAA-5 (total)drinking waterMAC80 µg/LDisinfection Byproducts- Haloacetic acidshigh
#P027physicaloperationalmandatoryMaximum Scour Concentrationwastewaterrequirement<= 25 mg/LInstallation Configuration for Inline OGSAt Maximum Tested Scour Flow Ratehigh
#P028designtreatmentmandatoryAnnual Rainfall Volume Capture Targetwastewatertreatment_goal90 %Sizing and Performance EvaluationBased on average annual rainfall volumehigh
#P029designoperationalmandatorySediment Storage Depth Factorwastewaterrequirement50 %Calculation of Maximum Treatment Depthhigh
#P030designoperationalmandatoryDesign Intensity Evaluation Rangewastewaterrequirement10-100 %Sizing and Performance Evaluation for OGSCorresponding to Annual Rainfall Volume Capturedhigh
#P031designtreatmentmandatoryMinimum Rainfall Capture Eventsotherrequirement>= 3 eventsDesign criteria for annual rainfall volume captureEvents must have rainfall intensity and depth corresponding to 90% average annual rainfall volumehigh
#P032designoperationalmandatoryBypass Design Flow Rate Thresholdwastewaterrequirement90 %Required threshold for calculating internal or diversion by-pass capacity relative to inlet pipe capacity.Applies to Inline OGS, Inline Filter, and Off-line installation configurations.high
#P033chemicalhealthmandatoryBromatedrinking waterMAC0.01 mg/LDisinfection Byproducts- Otherhigh
#P034chemicalhealthmandatoryBenzenedrinking waterMAC1 µg/LOrganic Parametershigh
#P035chemicalhealthmandatoryNDMAdrinking waterMAC0.009 µg/LOrganic Parametershigh
#P036chemicalhealthmandatoryGlyphosatedrinking waterMAC280 µg/LPesticideshigh
#P037chemicalhealthmandatoryAtrazine + N-dealkylated metabolitesdrinking waterMAC5 µg/LPesticideshigh
#P038chemicalhealthmandatoryXylenes (total) calculateddrinking waterMAC90 µg/LOrganic Parametershigh
#P039chemicalhealthmandatoryDichloromethane (Methylene Chloride)drinking waterMAC50 µg/LOrganic Parametershigh
#P040chemicalhealthmandatoryVinyl Chloridedrinking waterMAC1 µg/LOrganic Parametershigh
#P041operationalreportingmandatoryAnnual report submission deadlineotherrequirementApril 1 dateAnnual reports must be submitted for the year following the year being reported on.To be submitted to the appropriate Regional Aquaculture Management Officehigh
#P042operationalreportingmandatoryRequired annual reporting formsotherrequirement4 formsNumber of annual reporting forms required for submission.Submit no later than April 1high
#P043operationaltreatmentmandatoryMinimum flow-through exchange volumewastewater, aquatic liferequirement>= 300 %Percentage of tanks volumetric capacity used to exchange for effective flow through exchange.Applies when using the Flow Through Method (FTM) to meet the D-1 standard.high
#P044operationalreportingmandatoryBWRF Tank configurationsotherrequirement20, 30, 50 tanksThe Canadian Ballast Water Reporting Form is available in three specific configurations.Use the shortest form that allows for the total number of tanks/holds in the vessel's ballast water management plan.high

D Definitions (12)

Req ID Category Name Context Confidence
#D001Atrazine + N-dealkylated metabolitesAtrazine + Desethylatrazinehigh
#D002HAA5 (total)Bromoacetic acid + Chloroacetic acid + Dibromoacetic acid + Dichloroacetic acid + Trichloroacetic acidhigh
#D003PCB totalArochlor 1232 + 1242 + 1248 + 1254 + 1260 + 1262high
#D004THM (total)Bromodichloromethane + Bromoform + Chloroform + Dibromochloromethanehigh
#D005Xylenes (total)m- & p-Xylene + o-Xylenehigh
#D006P/APresence / Absencehigh
#D007mg/Lmilligrams per litrehigh
#D008µg/Lmicrograms per litrehigh
#D009TCUTrue Colour Unithigh
#D010NTUNephelometric Turbidity Unithigh
#D011CFUColony forming unithigh
#D012µmhos/cmMicromhos per centimeterhigh