| #Q001 | administrative | reporting | mandatory | General P2 Plan Submission | wastewater | Under Section 5 of the Sewers By-law, every industrial, commercial and institutional facility that discharges certain pollutants, known as “subject pollutants,” must prepare and submit a Pollution Prevent (P2) Plan using the forms outlined below under Reporting Requirements by Sector. | If facility discharges subject pollutants | high |
| #Q002 | reporting | reporting | mandatory | P2 Plan Content Requirements | wastewater | Plans require businesses to identify and quantify each subject pollutant, along with the activities taken to help minimize or avoid their use. | | high |
| #Q003 | operational | operational | mandatory | Best Management Practices Compliance | wastewater | Certain business sectors are also required to follow Best Management Practices, which outline specific operating standards. | Applies to certain business sectors as designated | high |
| #Q004 | administrative | reporting | mandatory | Subject Pollutant Discharges | wastewater | Companies must submit a Pollution Prevention Plan if they discharge any of the following: Metals... Organic Compounds... | If discharging specified metals or organic compounds | high |
| #Q005 | operational | operational | mandatory | Automotive Services BMP | wastewater | Facilities must: Follow the Best Management Practices (BMP) for Automotive Services Facilities. | Applies to automotive repair facilities, autobody shops, car washes, and gas stations | high |
| #Q006 | reporting | reporting | mandatory | Automotive Services Declaration Form | wastewater | Submit a one-time Declaration Form confirming compliance with the BMP. | | high |
| #Q007 | reporting | reporting | mandatory | Automotive Services Updated Declaration Form | wastewater | Submit a new Declaration Form if there is a change in location, ownership or operation (e.g. repair facility begins to offer autobody work). | If there is a change in location, ownership or operation | high |
| #Q008 | treatment | treatment | mandatory | Dental Amalgam Separator Installation | wastewater | Dental offices that handle amalgam (e.g. provide or remove amalgam fillings) are required to install and properly maintain an amalgam separator to capture and stop the heavy metals that make up amalgam from being discharged into the sanitary sewer. | Applies to dental offices that handle amalgam | high |
| #Q009 | reporting | reporting | mandatory | Dental Facilities P2 Plan Submission | wastewater | Offices must: Submit a one-time P2 Plan using the Dental Facilities P2 Form. | | high |
| #Q010 | reporting | reporting | mandatory | Dental Amalgam Separator Maintenance Invoices | wastewater | Submit ongoing invoices confirming cleaning and maintenance of the amalgam separator. | | high |
| #Q011 | reporting | reporting | mandatory | Dental Facilities Updated P2 Plan | wastewater | Submit a new P2 Plan if location or operations change (i.e. increase in the number of chairs). | If location or operations change | high |
| #Q012 | reporting | reporting | mandatory | Dry Cleaning P2 Plan Submission | wastewater | Facilities must: Submit a P2 Plan every six years, with an update on the third year of the six-year cycle, using the Dry Cleaning Facilities P2 Form. | | high |
| #Q013 | reporting | reporting | mandatory | Dry Cleaning Updated P2 Plan | wastewater | Submit a new P2 Plan if location, ownership or processes change. | If location, ownership or processes change | high |
| #Q014 | operational | operational | guidance | Supplier Verification for Subject Pollutants | wastewater | Facilities may need to contact suppliers to verify whether their products contain subject pollutants. | | high |
| #Q015 | reporting | reporting | mandatory | Health Care Institutions P2 Plan | wastewater | Institutions must: Submit a P2 Plan every six years, with an update on the third year of the six-year cycle, using the Health Care Sector P2 Form. | | high |
| #Q016 | operational | operational | mandatory | Photofinishing BMP Compliance | wastewater | Facilities must: Follow the Best Management Practices (BMP) for Photofinishing Operations. | | high |
| #Q017 | reporting | reporting | mandatory | Photofinishing Declaration Form | wastewater | Submit a one-time Declaration Form confirming compliance with the BMP. | | high |
| #Q018 | reporting | reporting | mandatory | Photofinishing Updated Declaration Form | wastewater | Submit a new Declaration Form if location or ownership changes. | If location or ownership changes | high |
| #Q019 | reporting | reporting | mandatory | Commercial Printers P2 Plan Submission | wastewater | Commercial printers must: Submit a P2 Plan every six years, with an update on the third year of the six-year cycle, using the Printing Facilities P2 Form. | | high |
| #Q020 | reporting | reporting | mandatory | Commercial Printers Updated P2 Plan | wastewater | Submit a new P2 Plan if the location changes. | If the location changes | high |
| #Q021 | reporting | reporting | mandatory | Industrial Printers Reporting Requirements | wastewater | Industrial printers must follow the reporting requirements listed for Industrial Facilities. | | high |
| #Q022 | reporting | reporting | mandatory | Industrial Facilities P2 Plan Submission | wastewater | Facilities must: Submit a P2 Plan every six years using the Pollution Prevention (P2) Form. | | high |
| #Q023 | reporting | reporting | mandatory | Industrial Facilities P2 Plan Update | wastewater | Submit an update on the third year of the six-year cycle using the P2 Plan Update Form. | | high |
| #Q024 | reporting | reporting | mandatory | Industrial Facilities Updated P2 Plan | wastewater | Submit a new P2 Plan if the location or operations change. | If the location or operations change | high |
| #Q025 | reporting | reporting | mandatory | Non-Sector Facilities P2 Plan Requirement | wastewater | In these instances, companies must submit the following for the facility in question: P2 Plan every six years using the Pollution Prevention (P2) Form. | Upon request from Toronto Water as a result of regular inspection or sampling | high |
| #Q026 | reporting | reporting | mandatory | Non-Sector Facilities P2 Plan Update | wastewater | A P2 Plan update on the third year of the six-year cycle using the P2 Plan Update Form. | Upon request from Toronto Water | high |
| #Q027 | reporting | reporting | mandatory | Non-Sector Facilities Updated P2 Plan | wastewater | A new P2 Plan if the location or operations change. | If the location or operations change, upon request from Toronto Water | high |
| #Q028 | administrative | reporting | mandatory | P2 Form Submission Contact Information | wastewater | Send Pollution Prevention forms to: Environmental Monitoring and Protection, 2126 Kipling Avenue, Toronto, ON M9W 4K5, Fax: 416-392-9338, Email: p3help@toronto.ca | Applicable for all P2 form submissions | high |
| #Q029 | operational | operational | guidance | Health Care Supplier Verification | wastewater | Institutions may need to contact suppliers to verify whether their products contain subject pollutants. | To verify presence of subject pollutants | high |
| #Q030 | operational | operational | guidance | Printing Supplier Verification | wastewater | Printers may need to contact suppliers to verify whether their products contain subject pollutants. | To verify presence of subject pollutants | high |
| #Q031 | operational | operational | guidance | Industrial Supplier Verification | wastewater | Companies may need to contact suppliers to verify whether their products contain subject pollutants. | To verify presence of subject pollutants | high |
| #Q032 | operational | operational | guidance | Non-Sector Supplier Verification | wastewater | Companies may need to contact suppliers to verify whether their products contain subject pollutants. | To verify presence of subject pollutants | high |