Parameter Viewer

Document ID ca-prler-2026-04-01 Title Petroleum Refinery Liquid Effluent Regulations URL https://laws-lois.justice.gc.ca/eng/regulations/C.R.C.%2C_c._828/FullText.html Jurisdiction /ca Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:39:51.105900+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (17)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativereportingmandatoryInitial Declaration of Reference Crude RatewastewaterWhen the owner of a refinery intends to deposit a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e), he shall, before making the deposit, sign, date and forward to the Minister a declaration, in such form as the Minister may prescribe, stating the reference crude rate of the refinery.When the owner of a refinery intends to deposit a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e)high
#Q002administrativereportingguidanceVoluntary Revision of Reference Crude RatewastewaterThe owner of a refinery may revise the reference crude rate of the refinery at any time by signing, dating and forwarding to the Minister a declaration, in such form as the Minister may prescribe, stating the revised reference crude rate of the refinery.at any timehigh
#Q003administrativereportingmandatoryMandatory Revision of Reference Crude RatewastewaterThe owner of a refinery that deposits a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall revise the reference crude rate of the refinery if the arithmetic mean of the stream day crude rates during any two consecutive months, divided by 1,000, excluding days when crude rates have been reduced due to refinery maintenance, is less than 85 per cent of the last declared reference crude rate of the refinery and shall sign, date and forward a declaration, in such form as the Minister may prescribe, stating the revised reference crude rate of the refinery.if the arithmetic mean of the stream day crude rates during any two consecutive months, divided by 1,000, excluding days when crude rates have been reduced due to refinery maintenance, is less than 85 per cent of the last declared reference crude rate of the refineryhigh
#Q004monitoringoperationalmandatoryDetermination of Actual DepositswastewaterFor the purposes of subsection 5(1), when the owner of a refinery deposits a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e), he shall, within 30 days after the end of the month in which the deposit is made, determine for that month the actual deposit of each substance deposited by the refinery by making the measurements and calculations in accordance with Schedule IV.within 30 days after the end of the month in which the deposit is madehigh
#Q005monitoringoperationalmandatoryDaily Monitoring of pHwastewaterThe owner of a refinery that deposits the deleterious substance prescribed in paragraph 4(f) shall, every day in the month during which the deposit is made or when requested by the Minister, monitor the deposit for the purpose of subsection 5(2) by performing the test referred to in Schedule III.every day in the month during which the deposit is made or when requested by the Ministerhigh
#Q006reportingreportingmandatoryMonthly Reporting of DepositswastewaterThe owner of a refinery that has deposited a deleterious substance prescribed in section 4 in any month shall sign, date and forward to the Minister within 30 days after the end of that month or when requested by the Minister, a report, in such form as the Minister may prescribe, indicating (a) the arithmetic mean of the authorized deposits of that substance in that month for the refinery as calculated in accordance with section 7 and, where applicable, section 9; (b) the authorized deposits of that substance in each day of that month for the refinery as calculated in accordance with sections 7 and 8 and, where applicable, section 9; (c) the actual deposits of the deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) deposited in each day of that month by the refinery as calculated in accordance with Schedule IV; (d) the arithmetic mean of the actual deposits of the deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) deposited in that month by the refinery as calculated in accordance with Schedule IV; (e) the pH of composite samples measured in accordance with Schedule III; (f) the reference crude rate of the refinery in that month; and (g) such other information as may be requested by the Minister to enable him to determine whether the refinery is operating in compliance with the requirements of these Regulations.within 30 days after the end of that month or when requested by the Ministerhigh
#Q007designoperationalmandatoryInstallation and Maintenance of Monitoring FacilitieswastewaterThe owner of a refinery that deposits a deleterious substance prescribed in section 4 shall install and maintain facilities including sampling connections and flow-measuring devices that are acceptable to the Minister to enable the Minister to determine whether the refinery is operating in compliance with the requirements of these Regulations.The owner of a refinery that deposits a deleterious substance prescribed in section 4high
#Q008monitoringoperationalmandatorypH Determination MethodwastewaterThe pH of composite samples obtained from each liquid effluent outfall and from the once-through cooling water shall be determined using (a) the test method prescribed in section 221 of the publication Standard Methods for the Examination of Water and Waste Water, 13th edition (1971), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation; or (b) another equivalent method, approved in writing by the Minister, the results of which can be confirmed by the method referred to in paragraph (a).high
#Q009monitoringoperationalmandatoryContinuous Flow Rate MeasurementwastewaterThe flow rates of all liquid effluents and once-through cooling water deposited by a refinery shall be measured and recorded continuously in Canadian gallons per minute.high
#Q010monitoringoperationalmandatoryConcentration Determination of Deleterious SubstanceswastewaterThe concentration in milligrams per litre of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) in composite samples obtained from each liquid effluent outfall and from the once-through cooling water shall be determined every Monday, Wednesday and Friday, or as requested by the Minister, using (a) the test method referred to in Column II of an item of the table to this Schedule and modified as set out in Column III of that item in respect of the deleterious substance set out in Column I of that item; or (b) any other equivalent method, approved in writing by the Minister, the results of which can be confirmed by the method referred to in paragraph (a).every Monday, Wednesday and Friday, or as requested by the Ministerhigh
#Q011monitoringoperationalrecommendedAdherence to Sampling ProcedureswastewaterFor the purpose of this section, procedures pertaining to sampling, the preservation and storage of samples and the prevention of interference, as outlined in the general sections relating to the specific test methods set out in Column II of the table to this Schedule, should be adhered to.high
#Q012operationaloperationalmandatoryCalculation of Actual DepositwastewaterThe actual deposit by a refinery of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall be calculated by using the amounts obtained under sections 1 and 2 of this Schedule for each day that the concentration of that deleterious substance has been determined.high
#Q013operationaloperationalmandatoryCalculation of Arithmetic Mean of Actual DepositswastewaterThe arithmetic mean of the actual deposits referred to in paragraph 5(1)(a) of the Regulations shall be calculated using the amounts obtained under section 3 of this Schedule.high
#Q014operationaloperationalmandatoryCalculation of Substance Quantity in Storm WaterwastewaterFor the purpose of subsection 5(3) of the Regulations, the actual quantity of a deleterious substance prescribed in paragraph 4(a), (b) or (e) of the Regulations contained in storm water deposited each month shall be calculated using the weighted average concentration, based on the quantity of storm water discharged for those days during which the concentration of that deleterious substance has been determined, and the total quantity of storm water discharged in that month.high
#Q015monitoringoperationalmandatoryTest Method Modification for Oil and GreasewastewaterIn 4 (a) use petroleum ether as the solvent; in 4 (c) dry on a steam bath at 100 °C.When testing for Oil and grease using APHA Section 137high
#Q016monitoringoperationalguidanceFiltered Sample Permission for Sulfide TestingwastewaterThis test may be carried out on a filtered sample.When testing for Sulfide using APHA Section 228C(b)high
#Q017monitoringoperationalguidanceVolatile Portion Substitution for Total Suspended MatterwastewaterDuring periods when storm water is being deposited, the volatile portion of total suspended matter determined by APHA Section 224D may be substituted for APHA Section 224C.During periods when storm water is being depositedhigh

P Quantitative Requirements (96)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001physicaltreatmentmandatorypHwastewaterrequirement6.0 - 9.5 pHLimits for the deposit of deleterious substances in liquid effluent or once-through cooling waterApplicable to authorized deposit of a deleterious substancehigh
#P002chemicaltreatmentmandatoryOil and Greasewastewaterrequirement3.0 pounds per 1,000 barrels of crude oilMonthly amount in calculating authorized depositsnullhigh
#P003chemicaltreatmentmandatoryOil and Greasewastewaterrequirement5.5 pounds per 1,000 barrels of crude oilOne day amount in calculating authorized depositsnullhigh
#P004chemicaltreatmentmandatoryOil and Greasewastewaterrequirement7.5 pounds per 1,000 barrels of crude oilMaximum daily amount in calculating authorized depositsnullhigh
#P005chemicaltreatmentmandatoryPhenolswastewaterrequirement0.3 pounds per 1,000 barrels of crude oilMonthly amount in calculating authorized depositsnullhigh
#P006chemicaltreatmentmandatoryPhenolswastewaterrequirement0.55 pounds per 1,000 barrels of crude oilOne day amount in calculating authorized depositsnullhigh
#P007chemicaltreatmentmandatoryPhenolswastewaterrequirement0.75 pounds per 1,000 barrels of crude oilMaximum daily amount in calculating authorized depositsnullhigh
#P008chemicaltreatmentmandatorySulfidewastewaterrequirement0.1 pounds per 1,000 barrels of crude oilMonthly amount in calculating authorized depositsnullhigh
#P009chemicaltreatmentmandatorySulfidewastewaterrequirement0.3 pounds per 1,000 barrels of crude oilOne day amount in calculating authorized depositsnullhigh
#P010chemicaltreatmentmandatorySulfidewastewaterrequirement0.5 pounds per 1,000 barrels of crude oilMaximum daily amount in calculating authorized depositsnullhigh
#P011chemicaltreatmentmandatoryAmmonia Nitrogenwastewaterrequirement3.6 pounds per 1,000 barrels of crude oilMonthly amount in calculating authorized depositsnullhigh
#P012chemicaltreatmentmandatoryAmmonia Nitrogenwastewaterrequirement5.7 pounds per 1,000 barrels of crude oilOne day amount in calculating authorized depositsnullhigh
#P013chemicaltreatmentmandatoryAmmonia Nitrogenwastewaterrequirement7.2 pounds per 1,000 barrels of crude oilMaximum daily amount in calculating authorized depositsnullhigh
#P014physicaltreatmentmandatoryTotal Suspended Matterwastewaterrequirement7.2 pounds per 1,000 barrels of crude oilMonthly amount in calculating authorized depositsnullhigh
#P015physicaltreatmentmandatoryTotal Suspended Matterwastewaterrequirement12.0 pounds per 1,000 barrels of crude oilOne day amount in calculating authorized depositsnullhigh
#P016physicaltreatmentmandatoryTotal Suspended Matterwastewaterrequirement15.0 pounds per 1,000 barrels of crude oilMaximum daily amount in calculating authorized depositsnullhigh
#P017chemicaltreatmentmandatoryOil and Greasewastewaterrequirement1.0 Pounds per 10,000 Canadian Gallons of Storm WaterAmounts to be used in calculating additional authorized deposits of deleterious substances when storm water is being dischargedWhen storm water is being dischargedhigh
#P018chemicaltreatmentmandatoryOil and Greasewastewaterrequirement25.0 Pounds per month per 1,000 barrels of crude oil per dayLimits of deposits authorized when storm water is being dischargedWhen storm water is being dischargedhigh
#P019chemicaltreatmentmandatoryPhenolswastewaterrequirement0.1 Pounds per 10,000 Canadian Gallons of Storm WaterAmounts to be used in calculating additional authorized deposits of deleterious substances when storm water is being dischargedWhen storm water is being dischargedhigh
#P020chemicaltreatmentmandatoryPhenolswastewaterrequirement2.5 Pounds per month per 1,000 barrels of crude oil per dayLimits of deposits authorized when storm water is being dischargedWhen storm water is being dischargedhigh
#P021physicaltreatmentmandatoryTotal Suspended Matterwastewaterrequirement3.0 Pounds per 10,000 Canadian Gallons of Storm WaterAmounts to be used in calculating additional authorized deposits of deleterious substances when storm water is being dischargedWhen storm water is being dischargedhigh
#P022physicaltreatmentmandatoryTotal Suspended Matterwastewaterrequirement75.0 Pounds per month per 1,000 barrels of crude oil per dayLimits of deposits authorized when storm water is being dischargedWhen storm water is being dischargedhigh
#P023physicaltreatmentmandatorypH (Sanitary and Combined Sewers)wastewaterrequirement> 6.0 to < 11.5 SULimits for sewage discharge into a sanitary or combined sewerStandard discharge conditionshigh
#P024physicaltreatmentmandatoryTemperature (Sanitary and Combined Sewers)wastewaterrequirement< 60 Degrees CelsiusLimits for sewage discharge into a sanitary or combined sewernullhigh
#P025chemicaltreatmentmandatoryBiochemical Oxygen Demand (Sanitary and Combined)wastewaterrequirement300 mg/LLimits for sewage discharge into a sanitary or combined sewerFive-day BOD determinationhigh
#P026physicaltreatmentmandatorySuspended Solids (Total) (Sanitary and Combined)wastewaterrequirement350 mg/LLimits for sewage discharge into a sanitary or combined sewernullhigh
#P027microbiologicalhealthmandatoryE. coli (Storm Sewer)recreational water, otherrequirement200 colonies per 100 mLMatter discharged into a storm sewer or watercoursenullhigh
#P028physicaloperationalmandatorypH (Storm Sewer)aquatic life, otherrequirement> 6.0 to < 9.5 SULimits for Storm Sewer Dischargenullhigh
#P029chemicaltreatmentmandatoryBiochemical Oxygen Demand (Storm Sewer)aquatic life, otherrequirement15 mg/LLimits for Storm Sewer Dischargenullhigh
#P030physicaltreatmentmandatorySuspended Solids (Total) (Storm Sewer)aquatic life, otherrequirement15 mg/LLimits for Storm Sewer Dischargenullhigh
#P031chemicalhealthmandatorySwimming Pool Chlorine Concentrationrecreational waterrequirement0.01 mg/LConditions for discharging wastewater from private residential swimming pools to storm sewersWater must be held for one week after last dosage of chlorinehigh
#P032chemicalhealthmandatorySwimming Pool Copper Concentrationrecreational waterrequirement0.04 mg/LConditions for discharging wastewater from private residential swimming pools to storm sewersnullhigh
#P033physicaloperationalmandatoryCombustible Liquid Flash Pointwastewater, otherrequirement>= 37.8 to <= 93.3 degrees CelsiusDefinition of combustible liquidnullhigh
#P034chemicaloperationalmandatoryIgnitable Waste Alcohol Percentagewastewaterrequirement< 24 percent alcohol by volumeDefinition of ignitable wasteAqueous solutionhigh
#P035chemicaltreatmentmandatoryArsenic (total) (Sanitary and Combined)wastewaterrequirement1 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P036chemicaltreatmentmandatoryCadmium (total) (Sanitary and Combined)wastewaterrequirement0.7 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P037chemicaltreatmentmandatoryMercury (total) (Sanitary and Combined)wastewaterrequirement0.01 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P038chemicaltreatmentmandatoryLead (total) (Sanitary and Combined)wastewaterrequirement1 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P039chemicaltreatmentmandatoryCyanide (total) (Sanitary and Combined)wastewaterrequirement2 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P040chemicaltreatmentmandatoryPhosphorus (total) (Sanitary and Combined)wastewaterrequirement10 mg/LLimits for Sanitary and Combined Sewers Dischargenullhigh
#P041chemicaltreatmentmandatoryArsenic (total) (Storm)aquatic liferequirement0.02 mg/LLimits for Storm Sewer Dischargenullhigh
#P042chemicaltreatmentmandatoryLead (total) (Storm)aquatic liferequirement0.12 mg/LLimits for Storm Sewer Dischargenullhigh
#P043chemicaltreatmentmandatoryMercury (total) (Storm)aquatic liferequirement0.0004 mg/LLimits for Storm Sewer Dischargenullhigh
#P044chemicaltreatmentmandatoryPCBs (Storm)aquatic liferequirement0.0004 mg/LLimits for Storm Sewer Dischargenullhigh
#P045operationalreportingmandatoryPollution Prevention Plan Durationotherrequirement6 yearsDuration of a pollution prevention plannullhigh
#P046operationalreportingmandatoryPollution Prevention Plan Submission Deadlineotherrequirement1 yearSubmission of first plan for subject sector industriesWithin one year of commencing operationshigh
#P047operationalreportingmandatorySpill Reporting Deadlineotherrequirement5 daysDeadline for submitting detailed written spill reportAfter the spill eventhigh
#P048operationaloperationalmandatorySewer Disconnection Notice Periodotherrequirement30 daysNotice period before temporary disconnection for violationsnullhigh
#P049operationalreportingmandatoryDocument Retention Periodotherrequirement7 yearsRetention period for documents required for inspection or approvalnullhigh
#P050operationaloperationalmandatoryStandard Penalty - First Offenceotherrequirement<= 50000 dollarsPenalty for contravention of chapter provisionsFirst offencehigh
#P051operationaloperationalmandatoryDischarge Penalty - Subsequent Offenceotherrequirement<= 100000 dollarsPenalty for contravention of discharge sections 681-2, 681-3, 681-4Subsequent offencehigh
#P052operationaloperationalmandatoryDaily Penalty - Continuing Offenceotherrequirement<= 10000 dollars per dayPenalty for each day that an offence continuesnullhigh
#P053operationaloperationalmandatoryComposite Sample Minimum Grab Sampleswastewater, agricultural water, aquatic life, recreational water, otherrequirement>= 3 grab samplesDefinition of a composite samplehigh
#P054operationaloperationalmandatoryGrab Sample Maximum Durationwastewater, agricultural water, aquatic life, recreational water, otherrequirement<= 15 minutesDefinition of a grab samplehigh
#P055operationalreportingmandatoryPollution Prevention Plan Update Frequencyotherrequirement3 yearsSubmission of a plan update evaluating progressFrom the date which the plan was required to be submittedhigh
#P056operationalreportingmandatoryNew Subject Pollutant Plan Update Deadlineotherrequirement90 daysUpdating plan when discharging a pollutant not in the approved planWithin 90 days of the dischargehigh
#P057operationalreportingmandatoryDental Amalgam Maintenance Proof Deadlineotherrequirement1 monthSubmission of proof of compliance with amalgam separator maintenanceNo later than one month after every maintenancehigh
#P058operationaloperationalguidanceIndustrial Waste Surcharge Permit Fee Thresholdwastewaterrequirement<= 500 dollarsAnticipated total fee allowing permit in place of agreementFor a one year or lesser termhigh
#P059operationaloperationalguidanceSanitary Discharge Permit Fee Thresholdwastewaterrequirement<= 20000 dollarsAnticipated total fee allowing permit in place of agreementFor a one year or lesser termhigh
#P060operationalreportingmandatorySurcharge Agreement Notification Periodwastewaterrequirement10 daysNotification of ownership change or agreement status changeWithin 10 days of the occurrencehigh
#P061designoperationalguidelineReconstructed Building Demolition Thresholdotherrequirement> 50 percentDefinition of substantial demolition for connection disconnection requirementsExterior walls of the first storey above grade removedhigh
#P062designoperationalguidanceMunicipal Sewer Connection Reuse Diameterwastewaterrequirement<= 150 mmMaximum diameter allowed for reuse of a municipal sewer connectionFor the purposes of servicing a residential dwellinghigh
#P063operationaloperationalmandatorySwimming Pool Wastewater Hold Timerecreational waterrequirement1 weekHolding period for pool water before discharge to storm sewerAfter the last dosage of chlorinehigh
#P064designoperationalguidelinePrivate Residential Pool Limitrecreational waterrequirement<= 5 single-family residencesDefinition of private residential swimming poolhigh
#P065chemicaltreatmentmandatorySanitary Fluoride Limitwastewaterrequirement10 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P066chemicaltreatmentmandatorySanitary Total Kjeldahl Nitrogen Limitwastewaterrequirement100 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P067physicaloperationalmandatoryStorm Sewer Temperature Limitaquatic liferequirement< 40 Degrees CelsiusLimits for Storm Sewer Dischargehigh
#P068chemicaltreatmentmandatoryStorm Sewer Total Phosphorus Limitaquatic liferequirement0.4 mg/LLimits for Storm Sewer Dischargehigh
#P069chemicaltreatmentmandatoryStorm Sewer Phenolics (4AAP) Limitaquatic liferequirement0.008 mg/LLimits for Storm Sewer Dischargehigh
#P070chemicaltreatmentmandatoryCopper (total) (Sanitary and Combined)wastewaterrequirement2 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P071chemicaltreatmentmandatoryZinc (total) (Sanitary and Combined)wastewaterrequirement2 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P072chemicaltreatmentmandatoryOil and grease - animal and vegetable (Sanitary and Combined)wastewaterrequirement150 mg/LLimits for Sanitary and Combined Sewers Discharge; non-mineralhigh
#P073chemicaltreatmentmandatoryOil and grease - mineral and synthetic (Sanitary and Combined)wastewaterrequirement15 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P074chemicaltreatmentmandatoryChromium (total) (Sanitary and Combined)wastewaterrequirement4 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P075chemicaltreatmentmandatoryNickel (total) (Sanitary and Combined)wastewaterrequirement2 mg/LLimits for Sanitary and Combined Sewers Dischargehigh
#P076chemicaltreatmentmandatoryCopper (total) (Storm)aquatic liferequirement0.04 mg/LLimits for Storm Sewer Dischargehigh
#P077chemicaltreatmentmandatoryZinc (total) (Storm)aquatic liferequirement0.04 mg/LLimits for Storm Sewer Dischargehigh
#P078chemicaltreatmentmandatoryCadmium (total) (Storm)aquatic liferequirement0.008 mg/LLimits for Storm Sewer Dischargehigh
#P079chemicaltreatmentmandatoryCyanide (total) (Storm)aquatic liferequirement0.02 mg/LLimits for Storm Sewer Dischargehigh
#P080physicaloperationalmandatoryIgnitable Waste Flash Pointwastewaterrequirement< 93 degrees CelsiusDefinition of ignitable waste liquidhigh
#P081operationalreportingguidelineApplication Review Durationotherrequirement8 - 12 weeksThe review and consideration of completed applications by Toronto Waterhigh
#P082operationaloperationalmandatorySanitary / Combined Sewer Discharge Feewastewaterrequirement57 percent of Block 1 water rateFee for the discharge of Private Water to the municipal sanitary or combined sewer systemhigh
#P083operationaloperationalmandatoryMinimum Annual Discharge Feewastewaterrequirement500.00 dollarsMinimum fee applied where total annual fee would be less than this amountFor one year or lesser termhigh
#P084operationalreportingmandatoryHydrogeological Report Discharge Thresholdotherrequirement> 50000 litres/dayThreshold requiring submission of a hydrogeological reporthigh
#P085operationaltreatmentmandatoryFlow Meter Accuracy Rangeotherrequirement98.0 - 102.0 percentAccuracy requirement for the registration of private water passing through the meterhigh
#P086designoperationalmandatoryFlow Meter Installation Heightotherrequirement60 - 120 cmHeight of flow meter installation above grade level for accessibilityhigh
#P087designoperationalmandatorySampling Access Point Sizeotherrequirement>= 25 mmRequired size for sampling access points such as hose bibs or ball valveshigh
#P088operationalreportingmandatoryWater Quality Sample Recencyotherrequirement<= 9 monthsMaximum allowable age of laboratory analysis samples at the time of applicationPrior to the date of applicationhigh
#P089operationalreportingmandatoryDischarge Log Submission Deadlineotherrequirement<= 7 calendar daysDeadline for digital submission of the Private Water Discharge Log FormFrom the end of the month to which it applieshigh
#P090operationalreportingmandatoryAdditional Information Response Deadlineotherrequirement<= 30 calendar daysDeadline to provide additional information requested by Toronto WaterFailing which the application is deemed abandonedhigh
#P091designoperationalmandatoryGroundwater Sampling Port Sizeotherrequirement>= 200 mmMinimum size for the separate sampling port used for monitoring groundwater dischargehigh
#P092operationaloperationalguidelineShort Term Discharge Approval Maximum Durationotherrequirement<= 1 yearGeneral expected duration for short term private water discharge activities like site remediation and construction dewateringIntended for discharge activities to be completed within a relatively short periodhigh
#P093operationaloperationalmandatoryFlow Meter Calibration Frequencyotherrequirement<= 12 monthsFlow measuring device must be calibrated within this period prior to the approved date of dischargeCalibration record must be delivered to the General Manager prior to any dischargehigh
#P094operationalreportingmandatoryNew Flow Meter Purchase Recencyotherrequirement<= 30 daysPurchase receipts for newly purchased and unused meters accepted in lieu of calibration certificates if purchased recentlyMeter must be unused and purchased within 30 days of applicationhigh
#P095operationaltreatmentguidelineLong Term Pre-treatment Verification Durationwastewaterrequirement6 - 9 monthsThe City will take samples of treated Private Water to verify the effectiveness of the pre-treatment system over this periodVerification occurs prior to the issuance of any Permit or Agreementhigh
#P096operationalreportingmandatoryFlow Meter Photo Submission Deadlineotherrequirement1 dayDigital photographs showing installed flow meter and initial totalizer reading must be sent to the CityOne day prior to the start of any discharge under the discharge approvalhigh

D Definitions (28)

Req ID Category Name Context Confidence
#D001ActAct means the Fisheries Act; (Loi)high
#D002actual depositactual deposit means the aggregate quantity, measured in pounds per day, of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) that is contained in all liquid effluent and once-through cooling water and that is actually deposited in any one day by a refinery; (rejet réel)high
#D003ammonia nitrogenammonia nitrogen means the nitrogen in ammonia that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 4 of the table to Schedule IV; (azote ammoniacal)high
#D004authorized depositauthorized deposit means the aggregate quantity, measured in pounds per day, of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) that is contained in all liquid effluent and once-through cooling water and that may be deposited in any one day by a refinery under the authority of these Regulations; (rejet autorisé)high
#D005ballast waterballast water means water, carried in a vessel for stability and seaworthiness, that is discharged from the vessel to a refinery prior to loading the vessel and includes water used for cargo or ballast tank cleaning; (eau de ballast)high
#D006crude oilcrude oil means virgin or naturally occurring unrefined petroleum and any hydrocarbons or mixture of hydrocarbons similar in composition to petroleum brought into a refinery for processing, but does not include hydrocarbons and residual fuels brought into a refinery primarily to meet the fuel requirements of that refinery or primarily for direct blending into finished products; (pétrole brut)high
#D007dayday means a period of 24 consecutive hours; (jour)high
#D008depositdeposit means to deposit or permit the deposit in water frequented by fish; (rejeter)high
#D009liquid effluentliquid effluent means, subject to subsection (3), waste water and includes process water, cooling tower blow-down, tank draining, ballast water, storm water, wastes from water treatment facilities and run-off from land used for the disposition of waste water and sludges associated with the operation of a refinery; (effluent)high
#D010MinisterMinister means the Minister of the Environment; (ministre)high
#D011oil and greaseoil and grease means the oil and grease that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 1 of the table to Schedule IV; (huiles et graisses)high
#D012once-through cooling wateronce-through cooling water means, subject to subsection (3), water that has been circulated once through heat exchangers, either singly or in series, for the purpose of removing heat from process streams and that is not intended to come into contact with the process streams; (eau de refroidissement non recyclée)high
#D013ownerowner means the owner or operator of a refinery or his authorized representative; (propriétaire)high
#D014phenolsphenols means the hydroxy derivatives of benzene and its condensed nuclei that result from the operation of a refinery, that are contained in liquid effluent or once-through cooling water from that refinery and that are determined to be present therein by the test method referred to in item 2 of the table to Schedule IV; (phénols)high
#D015process waterprocess water means water that is intended to come into contact with hydrocarbons or treating chemicals at a refinery; (eau de traitement)high
#D016reference crude ratereference crude rate means the quantity of crude oil, expressed in thousand barrels per day, that, in accordance with section 6, has been declared by the owner of a refinery to be the reference crude rate of the refinery; (taux de référence de brut)high
#D017refineryrefinery means facilities intended primarily for the separation and conversion of crude oil into products, including liquified petroleum gas, gasolines, naphthas, heating oils, fuel oils, asphalts, lubricating oils and greases, benzene, toluene, xylene, hydrogen, sulphur and coke, and includes blending, shipping and packaging facilities located on the refinery property and all properties developed for the operation of those facilities, but does not include facilities associated with the processing of natural gas or the production of synthetic petroleum originating from coal or bituminous sands; (raffinerie)high
#D018storm waterstorm water means, subject to subsection (2), water run-off that results from precipitation of any kind that falls on a refinery and includes water run-off originating from outside the refinery that passes over or through the refinery; (eaux pluviales)high
#D019stream day crude ratestream day crude rate means the rate, in barrels per day, at which crude oil is processed in a refinery; (taux de brut par jour de fonctionnement effectif)high
#D020sulfidesulfide means dissolved sulfide that results from the operation of a refinery that is contained in liquid effluent or once-through water from that refinery and that is determined to be present therein by the test method referred to in item 3 of the table to Schedule IV; (sulfures)high
#D021total suspended mattertotal suspended matter means the non-filterable residue that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 5 of the table to Schedule IV. (matières en suspension de toute nature)high
#D022reference crude rateFor the purpose of subsection (1), the reference crude rate of a refinery is the maximum design stream day crude rate of the refinery, divided by 1,000.high
#D023revised reference crude rateFor the purpose of subsection (3), the revised reference crude rate of a refinery is the arithmetic mean of stream day crude rates sustained in commercial operation for at least seven consecutive days, divided by 1,000.high
#D024revised reference crude rateFor the purpose of subsection (4), the revised reference crude rate of a refinery is the arithmetic mean of stream day crude rates sustained in commercial operation for at least 14 consecutive days, divided by 1,000.high
#D025composite sampleFor the purpose of subsection (1), a composite sample is (a) the quantity of liquid effluent or once-through cooling water that is collected continually during a sampling period of 24 hours at a rate in proportion to the flow rate of the liquid effluent or once-through cooling water; (b) the quantity of liquid effluent or once-through cooling water that is collected so that a minimum of 96 equal volumes of liquid are delivered into a receptacle at equal time intervals over a sampling period of 24 hours; or (c) in the case where the use of continuous stream analyzers have been approved by the Minister, the liquid effluent or once-through cooling water itself.medium
#D026effluenteffluent [has] the same meanings as in section 1 of the Wastewater Systems Effluent Regulations.high
#D027final discharge pointfinal discharge point [has] the same meanings as in section 1 of the Wastewater Systems Effluent Regulations.high
#D028wastewater systemwastewater system [has] the same meanings as in section 1 of the Wastewater Systems Effluent Regulations.high