Battery Manufacturing Effluent Guidelines

The EPA promulgated the Battery Manufacturing Effluent Guidelines and Standards (40 CFR Part 461Exit EPA’s website) in 1984 and amended the regulation in 1986. The regulation covers directdirectA point source that discharges pollutants to waters of the United States, such as streams, lakes, or oceans. and indirectindirectA facility that discharges pollutants to a publicly owned treatment works (municipal sewage treatment plant). dischargers. The Battery Manufacturing Effluent Guidelines and Standards are incorporated into NPDES permits for direct dischargers, and permits or other control mechanisms for indirect dischargers (see Pretreatment Program). On this page: * What is the Battery Manufacturing Industry? * Pollutants and Subcategories * Guidance Document * Rulemaking History * Additional Information


What is the Battery Manufacturing Industry?

Battery manufacturing encompasses the production of modular electric power sources where part or all of the fuel is contained within the unit and electric power is generated directly from a chemical reaction. There are three major components of a cell—anode, cathode, and electrolyte—plus mechanical and conducting parts such as case, separator, or contacts. Production includes electrode manufacture of anodes and cathodes, and associated ancillary operations necessary to produce a battery. Water is used in battery manufacturing plants in preparing reactive materials and electrolytes, in depositing reactive materials on supporting electrode structures, in charging electrodes and removing impurities, and in washing finished cells, production equipment, and manufacturing areas. Wastewater is generated from many processes within the plants, including formation area washdown, plate curing, product rinsing, cooling, equipment and floor area washing, laboratory washing, hand washing, laundry, truck washing, and wet scrubbers (air pollution controls). Diagram of Effluent Guidelines regulation coverage for metals industries Metals coverage under Effluent Guidelines
- Click to enlarge These activities are included within the following NAICS groups: * 335911: Storage Battery Manufacturing * 335912: Primary Battery Manufacturing

Note: the NAICS listing is provided as a guide and does not define the coverage of the Battery Manufacturing category. For precise definitions of coverage, see the applicability sections in 40 CFR Part 461Exit EPA’s website.


Pollutants and Subcategories

Regulated Pollutants

The regulated parameters vary by subcategory, and include: * Cadmium * Nickel * Silver * Zinc * Cobalt * Copper * Lead * Iron * Mercury * Manganese * Chromium * Cyanide * Oil and grease * TSS * COD * pH (abnormally high or low)

Some subcategories include zero discharge requirements.

Regulation Subcategories

The category is organized on the basis of anode material and electrolyte, with seven subcategories: * Cadmium (Subpart AExit EPA’s website) * Calcium (Subpart BExit EPA’s website) * Lead (Subpart CExit EPA’s website) * Leclanche (Subpart DExit EPA’s website) * Lithium (Subpart EExit EPA’s website) * Magnesium (Subpart FExit EPA’s website) * Zinc (Subpart GExit EPA’s website)


Guidance Document


Rulemaking History

1986 Amendment

Revised Subpart C pursuant to litigation * Final Rule (August 28, 1986)

1984 Initial Rulemaking


Additional Information

For additional information regarding the Battery Manufacturing Effluent Guidelines, please contact Erica Mason (mason.erica@epa.gov) or 202-566-2502.

Effluent Guidelines

Open Sidenav Menu Close Sidenav Menu Contact Us About Effluent Guidelines Contact Us About Effluent Guidelines to ask a question, provide feedback, or report a problem. Last updated on May 8, 2026 Welcome! Please share your feedback on how we can make www.epa.gov work better for you. A red asterisk (*) indicates a required field.

Success

Thank you. Your feedback has been received.

Error

alert message Required Questions - page 1 of 2 question_55203_answer_01 How would you rate your experience on www.epa.gov today? *

0 Stars 1 Star 2 Stars 3 Stars 4 Stars 5 Stars Please explain the reason for your rating. * 400 characters allowed Would you like to take two more minutes to answer more questions to help us improve our services? Yes, keep going → No, only submit these responses Optional questions - page 2 of 2 How would you describe yourself? Business Government employee Scientist Student Other Enter other text Please tell us why you visited www.epa.gov today. 400 characters allowed Did you visit www.epa.gov to accomplish a specific task? If yes, please explain why you were able or unable to accomplish your task. 400 characters allowed How can we make www.epa.gov a more helpful website? 400 characters allowed Submit [NAICS]: North American Industry Classification System [TSS]: total suspended solids [COD]: chemical oxygen demand [*]: required